Microwave Power Test; Transformer (T1) Primary Winding Test - Miele M 6160 TC Manual

Table of Contents

Advertisement

DTD no. 24-6160
Danger!
In order to ensure that no microwave energy can escape after any repair work
has been completed, the microwave oven must be thoroughly checked for
microwave leaks using a suitable microwave leak detector (mat. no. 05595470).
Particular care should be taken around the door and the casing edges.
The maximum permissible value is 5mW/cm
measured at a distance of 5cm (2 inches) from the oven with a water load of
3
275cm
±15cm
4.27

Microwave Power Test

A Fill a heat-resistant glass with 150mL water.
A Measure the initial temperature of the water (T
A Place the glass with the water in the center of the oven.
A Heat the water at full power for 60 s.
A Stir the water.
A Measure the final water temperature (T
A If the temperature increase (T
microwave power level is in order.
4.28

Transformer (T1) Primary Winding Test

A Removing the Microwave Oven from a Housing Unit, 001 4.4.
A Cover Removal, 001 4.5.
Danger!
For safety reasons, it is important to ensure that the high-voltage capacitor is
discharged by always short-circuiting it before starting any maintenance or
repair work. See .
A Disconnect the two primary winding connections on the transformer.
A Use an ohmmeter (in accordance with IEC 61010-1) to measure the
resistance between the two transformer terminals.
A The measured resistance must be approx. 2 .
01.10.2014, US_am
3
(0.073 gallons ± 0.004 gallons).
- T
E
This information should not be duplicated or passed on without Miele approval. All rights reserved.
Descriptive Technical Documentation
2
(32.3mW per square inch),
) with a digital thermometer.
A
) with a digital thermometer.
E
) is at least 50°C ± 5°C (90°F ± 9°F), the
A
001-51

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

M 6260 tcM 6262 tc

Table of Contents