Fine-Wire Fuse (F8) Removal - Miele M 6160 TC Manual

Table of Contents

Advertisement

DTD no. 24-6160
Fig. 24: Interference Suppression Filter
Danger!
In order to ensure that no microwave energy can escape after any repair work
has been completed, the microwave oven must be thoroughly checked for
microwave leaks using a suitable microwave leak detector (mat. no. 05595470).
Particular care should be taken around the door and the casing edges.
The maximum permissible value is 5mW/cm
measured at a distance of 5cm (2 inches) from the oven with a water load of
3
275cm
±15cm
4.19

Fine-Wire Fuse (F8) Removal

A Removing the Microwave Oven from a Housing Unit, 001 4.4.
Danger!
For safety reasons, it is important to ensure that the high-voltage capacitor is
discharged by always short-circuiting it before starting any maintenance or
repair work. See .
A Remove the 13 screws securing the air duct; see 001 Fig. 23.
A Remove the air duct.
A Remove the fine-wire fuse from the interference suppression filter; see 001
Fig. 25, Pos. 1.
01.10.2014, US_am
3
(0.073 gallons ± 0.004 gallons).
This information should not be duplicated or passed on without Miele approval. All rights reserved.
Descriptive Technical Documentation
2
(32.3mW per square inch),
001-41

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

M 6260 tcM 6262 tc

Table of Contents