DTD no. 24-6160
Warning!
Important during reassembly:
Ensure that components are positioned correctly, 001 Fig. 19.
Danger!
In order to ensure that no microwave energy can escape after any repair work
has been completed, the microwave oven must be thoroughly checked for
microwave leaks using a suitable microwave leak detector (mat. no. 05595470).
Particular care should be taken around the door and the casing edges.
The maximum permissible value is 5mW/cm
measured at a distance of 5cm (2 inches) from the oven with a water load of
3
275cm
±15cm
A Check the switch knob position in the service mode (service function b1); see
Service Mode, 001 4.3.
4.14
Control Electronic (N1) Removal
A Removing the Microwave Oven from a Housing Unit, 001 4.4.
A Cover Removal, 001 4.5.
Danger!
For safety reasons, it is important to ensure that the high-voltage capacitor is
discharged by always short-circuiting it before starting any maintenance or
repair work. See .
A Disconnect all connections from the control electronic.
A Remove the 2 T10 screws securing the control electronic to the electronics
mounting bracket; see 001 Fig. 20, Pos. 1.
01.10.2014, US_am
3
(0.073 gallons ± 0.004 gallons).
This information should not be duplicated or passed on without Miele approval. All rights reserved.