Magnetron (G2) Removal - Miele M 6160 TC Manual

Table of Contents

Advertisement

001-46
4.22

Magnetron (G2) Removal

A Removing the Microwave Oven from a Housing Unit, 001 4.4.
A Cover Removal, 001 4.5.
Danger!
For safety reasons, it is important to ensure that the high-voltage capacitor is
discharged by always short-circuiting it before starting any maintenance or
repair work. See .
A Disconnect all connections from the magnetron.
A Remove the T20 screw securing the magnetron temperature limiter mounting
bracket. See 001 Fig. 29, Pos. 1.
A Remove the mounting bracket from the magnetron.
A Remove the four T20 screws securing the magnetron; see 001 Fig. 29, Pos.
2.
A Remove the magnetron.
Fig. 29: Magnetron Screws
Danger!
In order to ensure that no microwave energy can escape after any repair work
has been completed, the microwave oven must be thoroughly checked for
microwave leaks using a suitable microwave leak detector (mat. no. 05595470).
Particular care should be taken around the door and the casing edges.
The maximum permissible value is 5mW/cm
measured at a distance of 5cm (2 inches) from the oven with a water load of
3
275cm
±15cm
This information should not be duplicated or passed on without Miele approval. All rights reserved.
3
(0.073 gallons ± 0.004 gallons).
Descriptive Technical Documentation
2
(32.3mW per square inch),
DTD no. 24-6160
01.10.2014, US_am

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

M 6260 tcM 6262 tc

Table of Contents