4. Set up Instruction

On/Off
Power on
Turn on
Turn off (Restore to factory setting) Press and hold the function key for 5 seconds till green indicator flashes 20 times.
Power off
Note
Network Joining
If the device has never joined the
network
If the device has joined the network
and it is not set to default
If the device fails to join the network
(when the device is turned on)
Function Key
Press the function key and hold the
pressing for 5 seconds
Press the function key once
Sleeping Mode
The device is turned on and in the
network
Low Voltage Warning
Low Voltage
Insert batteries. (users may need a screwdriver to open)
Press and hold the function key for 3 seconds till the green indicator flashes once.
Remove Batteries.
1.The device will be off after removing the battery and insert it again.
2.It is suggested to wait for at least 10 seconds between turning the device on and off.
st
th
3.At 1
-5
second after power on, the device will be in engineering test mode.
Turn on the device, and it will search for the network to join.
The green indicator light stays on for 5 seconds: joins the network successfully
The green indicator light remains off: fail to join the network
Turn on the device, and it will search for the previous network to join.
The green indicator light stays on for 5 seconds: joins the network successfully
The green indicator light remains off: fail to join the network
It is suggested to check the device verification information on the gateway or consult your
platform server provider when the device fails to join the network.
The device will be set to default and turned off
The green indicator light flashes 20 times: success
The green indicator light remains off: fail
The device is in the network: green indicator light flashes once and sends a report
The device is not in the network: green indicator light remains off
Sleep period: Min Interval.
When the reportchange exceeds setting value or the state changes: send a data report according
to Min Interval.