  • Page 1 Model: R718NL3 Wireless Light Sensor and 3-Phase Current Meter Wireless Light Sensor and 3-Phase Current Meter R718NL3 User Manual...
  • Page 2: Table Of Contents

    Table of Content 1. Introduction ................................2 2. Appearance ................................3 3. Main Features ................................3 4. Set up Instruction ..............................4 5. Data Report ................................5 6. Installation ................................9 7. Information about Battery Passivation ......................... 12 7.1 To determine whether a battery requires activation ..................12 7.2 How to activate the battery ..........................
  • Page 3: Introduction

    1. Introduction The R718NL3 series is a Light Sensor and 3-Phase Current Meter device for Netvox ClassA type devices based on the LoRaWAN open protocol and is compatible with the LoRaWAN protocol. R718NL3 series have different measuring range for different variety of CT.
  • Page 4: Appearance

    ⚫ Low power consumption and long battery life Note: Battery life is determined by the sensor reporting frequency and other variables, please refer to http://www.netvox.com.tw/electric/electric_calc.html On this website, users can find battery life time for varied models at different configurations.
  • Page 5: Set Up Instruction

    4. Set up Instruction On/Off Power on Insert batteries. (users may need a screwdriver to open) Turn on Press and hold the function key for 3 seconds till the green indicator flashes once. Turn off (Restore to factory setting) Press and hold the function key for 5 seconds till green indicator flashes 20 times. Power off Remove Batteries.
  • Page 6: Data Report

    (1) The device report interval will be programmed based on the default firmware which may vary. (2) The interval between two reports must be the minimum time. Please refer Netvox LoRaWAN Application Command document and Netvox Lora Command Resolver http://cmddoc.netvoxcloud.com/cmddoc to resolve uplink data.
  • Page 7 Version– 1 byte –0x01——the Version of NetvoxLoRaWAN Application Command Version DeviceType– 1 byte – Device Type of Device The devicetype is listed in Netvox LoRaWAN Application Devicetype doc ReportType – 1 byte –the presentation of the NetvoxPayLoadData,according the devicetype NetvoxPayLoadData– Fixed bytes (Fixed =8bytes)
  • Page 8 (00): Reserved Note: 1.When the current which is detected by the R718NL3 series exceeds 65535mA, the Multiplier column will be displayed as “10”.(Because the current value of the payload is 2 bytes, it can be displayed up to 0xFFFF.) 2.
  • Page 9 8199010000000000000000 (Configuration failed) (2) Read device configuration parameters Downlink: 0299000000000000000000 The device returns:8299003C003C0064006400 (current device configuration parameters) 5.3 Example for MinTime/MaxTime logic Example#1 based on MinTime = 1 Hour, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange=0.1V MaxTime MaxTime Sleeping(MinTime) Sleeping(MinTime) Wake up and collects data Wakes up and collects data Wakes up and collects data...
  • Page 10: Installation

    1. When using it, the back of it can be adsorbed on the iron surface, or the two ends can be fixed to the wall with screws. 2. When installing the R718NL3 series current transformer, please separate the live and neutral wires of the wire to be detected,...
  • Page 11 4. The three-phase current detector (R718NL3) samples the range, select a model with a higher measurement range. current according to MinTime. If the current value sampled The three-phase current detector (R718NL3) is suitable for the this time relatively exceeds the set value (the default is following scenarios: 100mA) more than the current value reported last time, the ⚫...
  • Page 12 Current Direction The CT terminal should be close to the power terminal as much as possible. R718NL3 Phase A Screw Wire to be Fixation detected Screw Fixation Current Direction Current Direction Phase B Phase C The CT terminal should be close...
  • Page 13: Information About Battery Passivation

    7. Information about Battery Passivation Many of Netvox devices are powered by 3.6V ER14505 Li-SOCl2 (lithium-thionyl chloride) batteries that offer many advantages including low self-discharge rate and high energy density. However, primary lithium batteries like Li-SOCl2 batteries will form a passivation layer as a reaction between the lithium anode and thionyl chloride if they are in storage for a long time or if the storage temperature is too high.
  • Page 14: Important Maintenance Instruction

    8. Important Maintenance Instruction Kindly pay attention to the following in order to achieve the best maintenance of the product: • Keep the device dry. Rain, moisture, or any liquid might contain minerals and thus corrode electronic circuits. If the device gets wet, please dry it completely.