4. Set up Instruction
On/Off
Power on
Turn on
Turn off (Restore to factory setting) Press and hold the function key for 5 seconds and the green indicator flashes 20 times.
Power off
Note:
Network Joining
Never joined the network
Had joined the network
Fail to join the network
(when the device is on)
Function Key
Press and hold for 5 seconds
Press once
Sleeping Mode
The device is on and in the network
Low Voltage Warning
Low Voltage
Insert batteries (Users may need a screwdriver to open)
Press and hold the function key for 3 seconds and the green indicator flash once.
Remove Batteries.
1. Remove and insert the battery; the device is at off state by default.
2. On/off interval is suggested to be about 10 seconds to avoid the interference of
capacitor inductance and other energy storage components.
3. For the first 5 second after powering on, the device will be in engineering test mode.
Turn on the device to search the network to join.
The green indicator stays on for 5 seconds: success
The green indicator remains off: fail
Turn on the device to search the previous network to join.
The green indicator stays on for 5 seconds: success
The green indicator remains off: fail
Suggest to check the device verification information on the gateway or consult your
platform server provider.
Restore to factory setting / Turn off
The green indicator flashes 20 times: success
The green indicator remains off: fail
The device is in the network: the green indicator flashes once and sends a report
The device is not in the network: the green indicator remains off
Sleeping period: Min Interval.
When the reportchange exceeds setting value or the state changes: send a data report
according to Min Interval.
3.2V