netvox R718VA User Manual

netvox R718VA User Manual

Wireless capacitive proximity sensor
Hide thumbs Also See for R718VA:

Advertisement

Quick Links

Model:R718VA
Wireless Capacitive Proximity Sensor
Wireless Capacitive Proximity Sensor
R718VA
User Manual

Advertisement

Table of Contents
loading

Summary of Contents for netvox R718VA

  • Page 1 Model:R718VA Wireless Capacitive Proximity Sensor Wireless Capacitive Proximity Sensor R718VA User Manual...
  • Page 2: Table Of Contents

    Table of Content 1. Introduction ....................................... 2 2. Appearance ......................................2 3. Main Features ....................................3 4. Application ......................................3 5. Set up Instruction ....................................4 6. Data Report ....................................... 5 7. Application Scenario ..................................8 8. Installation ......................................8 8.1 Measured liquid medium viscosity ............................
  • Page 3: Introduction

    1. Introduction R718VA is a device to detect the status of toilet water, hand sanitizer level, presence or absence of tissue. This device is connected with a non-contact capacitive sensor can be mounted to the exterior of the container, without direct contact with the object to be detected, which may detect the current water level of positions mounted, or the presence or absence of liquid soap or tissue;...
  • Page 4: Main Features

    Low power consumption and long battery life Note*: Battery life is determined by the sensor reporting frequency and other variables. Please refer to http://www.netvox.com.tw/electric/electric_calc.html On this website, users can find various types of battery lifetime in different configurations. 4. Application ...
  • Page 5: Set Up Instruction

    5. Set up Instruction On/Off Insert batteries. Power on (users may need a flat blade screwdriver to open) Turn on Press and hold the function key for 3 seconds till the green indicator flashes once. Turn off Press and hold the function key for 5 seconds till the green indicator flashes for 20 times. (Restore to factory setting) Power off Remove Batteries.
  • Page 6: Data Report

    When the liquid level changes from where the device cannot detect to where the device can detect. (0→1) If none of the above conditions is met, the device will report at the MaxTime interval. For the analysis of the data command reported by the device, refer to the Netvox LoRaWAN Application Command document and http://www.netvox.com.cn:8888/page/index.
  • Page 7 MaxTime BatteryChange Reserved ConfigReportReq 0x01 (2bytes Unit:s) (2bytes Unit:s) (1byte Unit:0.1v) (4Bytes,Fixed 0x00) Status Reserved ConfigReportRsp 0x81 (0x00_success) (8Bytes,Fixed 0x00) R718VA 0x9F Reserved ReadConfigReportReq 0x02 (9Bytes,Fixed 0x00) MinTime MaxTime BatteryChange Reserved ReadConfigReportRsp 0x82 (2bytes Unit:s) (2bytes Unit:s) (1byte Unit:0.1v) (4Bytes,Fixed 0x00) (1) Configure the device report parameters MinTime = 1min, MaxTime = 1min, BatteryChange = 0.1v...
  • Page 8 Example#2 based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange= 0.1V. MaxTime Sleeping(MinTime) sleeping sleeping sleeping Wakes up and Wakes up and Wakes up and Wakes up and Wakes up and collects data collects data collects data collects data collects data REPORT 3.6V...
  • Page 9: Application Scenario

    8. Installation Wireless Capacitive Proximity Sensor (R718VA) has two magnets on back. When using it, the back of it can be adsorbed a ferromagnetic material object, or the two ends can be fixed to the wall with screws (should be...
  • Page 10: Requirements Of Container And Installation Instruction

    3. Tank type: spherical tank, horizontal tank, vertical tank, etc. 4. The container of this kinds of materials is as following Picture 1: Plastic, glass, ceramics, etc. non-metallic container R718VA Mucilage glue R718VA Picture 1 Example of the installation method of the sensor with the non-metallic container...
  • Page 11 Picture 2. Copper, iron, stainless steel metal material water tower, boiler etc. metallic container Rubber plug R718VA Mucilage glue R718VA Picture 2 Example of the installation method of the sensor with the metallic container...
  • Page 12 “Installation method of the metal container”. For the installation method, see 8.2.2 and Picture 2, or install the sensor by external piping. See Picture 3 and Picture 4 for example. Rubber plug R718VA Mucilage glue R718VA Branch tee outlet...
  • Page 13: Adjust Sensitivity

    Rubber plug R718VA Mucilage glue Metal water pipe Picture 5 The installation example of the sensor installed on the branch tee outlet of metal water pipes Rubber tube R718VA Mucilage glue Picture 6 The sensor is directly attached to the rubber tube 8.3 Adjust sensitivity...
  • Page 14: Precautions For Battery Use

    8.4 Precautions for battery use Because the passivation of the ER battery electrode surface is an inherent characteristic of lithium thionyl chloride batteries, before using the ER14505 3.6V 2400mAh lithium thionyl chloride battery, the user can use a 33 ohm resistor to activate the battery for 1 minute to actively eliminate the battery hysteresis.

Table of Contents