1. Introduction R718VA is a device to detect the status of toilet water, hand sanitizer level, presence or absence of tissue. This device is connected with a non-contact capacitive sensor can be mounted to the exterior of the container, without direct contact with the object to be detected, which may detect the current water level of positions mounted, or the presence or absence of liquid soap or tissue;...
Low power consumption and long battery life Note*: Battery life is determined by the sensor reporting frequency and other variables. Please refer to http://www.netvox.com.tw/electric/electric_calc.html On this website, users can find various types of battery lifetime in different configurations. 4. Application ...
5. Set up Instruction On/Off Insert batteries. Power on (users may need a flat blade screwdriver to open) Turn on Press and hold the function key for 3 seconds till the green indicator flashes once. Turn off Press and hold the function key for 5 seconds till the green indicator flashes for 20 times. (Restore to factory setting) Power off Remove Batteries.
When the liquid level changes from where the device cannot detect to where the device can detect. (0→1) If none of the above conditions is met, the device will report at the MaxTime interval. For the analysis of the data command reported by the device, refer to the Netvox LoRaWAN Application Command document and http://www.netvox.com.cn:8888/page/index.
Page 8
Example#2 based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange= 0.1V. MaxTime Sleeping(MinTime) sleeping sleeping sleeping Wakes up and Wakes up and Wakes up and Wakes up and Wakes up and collects data collects data collects data collects data collects data REPORT 3.6V...
8. Installation Wireless Capacitive Proximity Sensor (R718VA) has two magnets on back. When using it, the back of it can be adsorbed a ferromagnetic material object, or the two ends can be fixed to the wall with screws (should be...
3. Tank type: spherical tank, horizontal tank, vertical tank, etc. 4. The container of this kinds of materials is as following Picture 1: Plastic, glass, ceramics, etc. non-metallic container R718VA Mucilage glue R718VA Picture 1 Example of the installation method of the sensor with the non-metallic container...
Page 11
Picture 2. Copper, iron, stainless steel metal material water tower, boiler etc. metallic container Rubber plug R718VA Mucilage glue R718VA Picture 2 Example of the installation method of the sensor with the metallic container...
Page 12
“Installation method of the metal container”. For the installation method, see 8.2.2 and Picture 2, or install the sensor by external piping. See Picture 3 and Picture 4 for example. Rubber plug R718VA Mucilage glue R718VA Branch tee outlet...
Rubber plug R718VA Mucilage glue Metal water pipe Picture 5 The installation example of the sensor installed on the branch tee outlet of metal water pipes Rubber tube R718VA Mucilage glue Picture 6 The sensor is directly attached to the rubber tube 8.3 Adjust sensitivity...
8.4 Precautions for battery use Because the passivation of the ER battery electrode surface is an inherent characteristic of lithium thionyl chloride batteries, before using the ER14505 3.6V 2400mAh lithium thionyl chloride battery, the user can use a 33 ohm resistor to activate the battery for 1 minute to actively eliminate the battery hysteresis.