Page 1
L52 – Manual Thank you for choosing a product from Standby. Technical Data Lens Polycarbonate Color Blue, Amber, Red, White Diodes 6 high power LED Cable 2 m, basic version Power 10-30 V DC Ambient temperature -40ºC to +85ºC Power consumption Peak value: 0.5 A @ 13.8 VDC, 0.5 A @ 27,6V DC...
L52 – Manual Flash Pattern Introduction The flash pattern setting controls the flash pattern. There are four versions of flash pattern: Double, Triple, Steady burn 1 and Steady burn 2. Double and Triple are built-in flash patterns and no control system is needed.
Page 3
L52 – Manual 5. Within 1 to 6 sec: temporarily connect the white wire to ground and let it stay connected for at least 2 sec. The lamp enters configuration mode and a flash sequence indicating the current settings starts.
L52 – Manual Sync Mode Introduction The sync mode setting controls how the flashing of two or more lamps is synchronized. There are two versions of sync mode: Simultaneous and Alternate. Simultaneous means that the lamps are in sync, that is they come on and go off at the same time.
Page 5
L52 – Manual 5. Within 1 to 6 sec: temporarily connect the white wire to ground and let it stay connected for at least 2 sec. The lamp enters configuration mode and a flash sequence indicating the current settings starts.
Page 6
L52 – Manual Factory Reset Introduction The settings can be changed back to the factory settings. The factory settings are the following: Flash pattern – Double Sync mode - Simultaneous Reset to Factory Settings WARNING Risk of eye damage. Do not look into the beam at close range.
Page 7
L52 – Manual 5. Within 1 to 6 sec: temporarily connect the white wire to ground and let it stay connected for at least 2 sec. The lamp enters configuration mode and a flash sequence indicating the current settings starts.
Page 8
L52 – Manual Connections The function of each wire and how to connect the wires depend on the chosen flash pattern setting. Table 1. Connections if flash pattern Double or Triple is selected. Wire Functions Connect to Black Power supply...
Page 9
L52 – Manual Table 2. Connections if flash pattern Steady burn 1 is selected. Wire Functions Connect to Black Power supply Good and suitable ground Power supply 10-30 V DC via a 5 A fuse White Lamp on/off Sinking output (-) of an...
L52 – Manual Installation CAUTION The lamp must be mounted on a flat surface. To prevent moisture from entering the lamp through the cable end, make sure that the cable end is sealed or located in a dry part of the vehicle.
Need help?
Do you have a question about the L52 and is the answer not in the manual?