The Bluetooth brand name is the property of Bluetooth ® SIG, Inc, which has licensed the use of these brands by Mahr GmbH. Other brand names and trade names are the property of their respective owners. Mahr GmbH, Digimar 817 CLT...
Thank you for placing your trust in us by purchasing this product. Update The latest version of the software, firmware, and quick guide is available to download on our homepage (Mahr.com/products/). Please note the relevant notes about the version when updating software and firmware. Updated...
Any extension cables must meet the stipulations of the VDE (German Association for Electrical, Electronic & Information Technologies). 9. Only Mahr-trained service personnel are permitted to carry out work on this instrument. Protective covers must only be removed by trained technicians and only when servicing is required.
Page 6
Do not allow any fluids to penetrate the instrument. 11. Inspect the connecting cables for damage. Change damaged cables immediately (Mahr service personnel). 12. Never move the height measuring instrument forcefully at the edge of the measuring plate. The air cushion at the edge does not dissipate quickly enough to slow down the movement of the height measuring instrument.
Alphabetical index ..... 32 4.1 Initial commissioning ......19 4.1.1 Switching ON ......19 4.1.2 Basic settings ......19 4.2 Reference point run ......20 4.3 Calibrate the probe ......20 4.4 Zero point on the measuring plate..21 Mahr GmbH, Digimar 817 CLT...
C Connecting cable for control panel MarConnect duplex interface. D Carrier for measuring anvils E Battery F Cylinder head screws and Allen key G AC adapter with plug adapter H Protective cover I Blind caps Mahr GmbH, Digimar 817 CLT...
Align the carriers for measuring anvils and undo the measuring slide fixture 180° Unpack the columns of the height measuring instrument 350 mm 25 kg 30 kg 600 mm 35 kg 1000 mm Remove the guard bracket 2x ( I ) Mahr GmbH, Digimar 817 CLT...
Page 10
Unpack the AC adapter Insert the battery 90° Euro click – Secure and connect the control panel Mahr GmbH, Digimar 817 CLT...
Page 11
Connect the AC adapter 100-240 V ~ / 50-60 Hz ~ 6,5 h Mahr GmbH, Digimar 817 CLT...
3 Control panel with on/off switch panel. 4 Quick measurement function keys and thumbwheel 5 Ports (back of instrument) 6 Handles on both sides (with button for air bearing) Mahr GmbH, Digimar 817 CLT...
2.4 Carrier for measuring anvils The carrier for the measuring anvils can be used to hold different anvils. The instrument comes with standard holder 817 h1 and measuring probe K5/51. Other carriers and measuring anvils are available as accessories. Mahr GmbH, Digimar 817 CLT...
There is a button fitted on the handle of the height measuring instrument to activate the air bearing. Fig. 8 Moving the height measuring instrument using the activated air bearing Fig. 6 Button for activating the air bearing Mahr GmbH, Digimar 817 CLT...
(Duplex interface for measuring perpendicularity and straightness). • USB 3.1 sockets (type B) For connecting: Fig. 9 − Mahr measuring equipment Millimess port (1086/16EWR/40EWR) 1 Measuring slide − USB memory stick with firmware 2 Millimess socket...
The menu bar is on the right-hand edge of the user interface and contains the following buttons and display elements: Opens the "Settings" menu for defining the software settings. Switches the context-sensitive online help on or off. Allows you to set zero points. Mahr GmbH, Digimar 817 CLT...
Preset entry 1 Menu bar 2 Current measuring value 3 Measuring value list 4 Function key bar When measuring program mode is activated, elements for managing measuring programs and results files are displayed in the information area. Mahr GmbH, Digimar 817 CLT...
Page 18
Calculate absolute result values for "Min-Max function" Enable measuring program mode Set X-value and Z-value to zero, e.g. in "perpendicularity measurement" Output measuring results as measuring record file in PDF format Output measuring results as Text file Mahr GmbH, Digimar 817 CLT...
Page 19
Intersection point Copies all results files to the connected USB memory stick Distance Output measuring results as measuring record file in PDF format Output measuring results as Text file Mahr GmbH, Digimar 817 CLT...
Page 20
"Shaft top" measuring function "Groove" measuring function "Ledge" measuring function "Bore center" measuring function Function "Base zero point measuring plate" "Distance calculation" calculation function "Symmetry calculation" calculation function "Delay" function "Set zero point workpiece" calculation function Mahr GmbH, Digimar 817 CLT...
Calibrate cone probe • The measuring probe automatically moves to the relevant height for the calibration process, e.g. to the height of the groove center of the setting gage when the "Calibrate with groove" function is selected. Mahr GmbH, Digimar 817 CLT...
• Press the button for the zero point to be set in the function key bar: Zero point 01 workpiece Zero point 02 workpiece Zero point 03 workpiece • Press the button in the menu bar to set the workpiece zero point. Mahr GmbH, Digimar 817 CLT...
The graph can be switched on or off by pressing the button. The individual measuring functions in 2D mode are explained in detail in the online help of the Digimar software. Mahr GmbH, Digimar 817 CLT...
• After contacting, the measured value is accepted and displayed in the top section of the information area. A measurement in quick mode can be aborted at any time by pressing the button in the menu bar of the user interface. Mahr GmbH, Digimar 817 CLT...
Measuring results can be saved in PDF and/ the "Programs" screen appears. or Text files. The online help of the Digimar software explains in detail how to create and output PDF and Text files. Fig. 15 "Programs" screen Mahr GmbH, Digimar 817 CLT...
The air bearings can be cleaned with The height measuring instrument methylated spirits (alcohol). should always be operated with the battery inserted. Mahr GmbH, Digimar 817 CLT...
12 VDC / 3.8 A / Type FW7405M/12 Supply voltage / mains frequency 110 - 230 V AC / 50 - 60 Hz Operating time, maximum 14 h Battery voltage 7.2 V Battery capacity 11500 mAh Rechargeable battery type Lithium-ion battery Protection rating IP40 Mahr GmbH, Digimar 817 CLT...
Dimensions (D x W x H) in 255 x 278 x 688 255 x 278 x 938 255 x 278 x 1338 Fig. 16 Instrument dimensions A 89.2 mm B 278 mm C 77 mm D 255 mm E 688 mm | 938 mm | 1338 mm F 0 - 350 mm | 0 - 600 mm | 0 - 1000 mm Mahr GmbH, Digimar 817 CLT...
KM 2, TMT 120, TMT 120 S ø 1.0 mm, carbide, l = 14.5 mm 4305850 Measuring anvil 800 ts KM 2, TMT 120, TMT 120 S ø 2.0 mm, carbide, l = 14.5 mm 4305871 Measuring anvil 800 ts KM 2, TMT 120, TMT 120 S ø 3.0 mm, carbide, l = 14.5 mm 4309051 Measuring anvil 800 tsr KM 2, TMT 120, TMT 120 S ø 2.0 mm, ruby, l = 14.5 mm Mahr GmbH, Digimar 817 CLT...
– 4429421 Depth probe, pivotable TMT 120 S ø 6 mm – 3015918 Probe shoe, TS 0.5/78 ø 4 mm Holder Gk/8 d = 0.5 mm, l = 78 mm 3015919 Stylus/stylus tip, T 1.2/75 ø 4 mm Holder Gk/8 d = 1.2 mm, l = 75 mm, ls = 15.5 mm 4429256 Probe holder incl. KM 2 Carrier 817h1/h2 measuring anvil ø 2.0 mm Mahr GmbH, Digimar 817 CLT...
Printer paper, 12 rolls 4102220 USB adapter for MarConnect Wireless i-stick 4221525 Test plate made of granite, 1,000 x 630 mm 107 G 4221573 Safety frame, 1,000 x 630 mm 107 Ug 4221526 Test plate made of granite, 1,200 x 800 mm 107 G 4221574 Safety frame, 1,200 x 800 mm 107 Ug Mahr GmbH, Digimar 817 CLT...
Cleaning ............25 Insert the battery ..........8 Commissioning ..........19 Instrument settings ........19 Confirm action ..........14 I-stick ..............13 Connection options ........13 Context-sensitive online help ...... 14 Control panel ..........10 Language ............19 Mahr GmbH, Digimar 817 CLT...
Page 35
Mahr measuring equipment ......13 Safety instructions .......... 3 Maintenance and care ........25 Scope of delivery ..........6 Manage results files ........17 Settings ............19 Managing measuring programs ....17 Set zero points ..........15 Measuring functions in 2D mode ..17, 22 Show data transfer ........
Need help?
Do you have a question about the Digimar 817 CLT and is the answer not in the manual?
Questions and answers