INSTALLATION INSTRUCTIONS
FUNCTIONAL TRAINER
1.
Read these instructions.
2. Heed all warnings.
3. Follow all instructions.
4. Professional installation is required by qualified personnel as dictated by authority having jurisdiction.
5. Proper installation is the responsibility of the installer.
6. Product failure due to improper installation is not covered under warranty.
7. It is the responsibility of the facility owner to adhere to local and regional building codes.
8. Follow all safety and installation instructions of the anchor and adhesive manufacturers.
9. Equipment must be mounted on level, solid concrete floor, minimum 5 inches (127 mm) thick.
10. All anchors must have a minimum embedment into concrete, regardless of any rubber/carpet/artificial turf, including
underlayment covering the concrete. If mounting the equipment over floor covering, use appropriate length screw anchors
(not supplied), along with the steel spacers provided, to bridge any gap between the concrete floor and the Floor Mount Plate.
11. Wear appropriate personal protective equipment (PPE); observe all governing codes and ordinances.
12. Safety Glasses required during installation.
13. Use a dust collection system when drilling; clean area using a HEPA vacuum. Avoid breathing dust.
14. Heavy Equipment: The Floor-mounted Functional Trainer weighs 118 lbs (54 kg). Help is required when handling the
Functional Trainer to prevent potential muscle strain and/or back injury.
15. Crush Hazard: Keep feet clear when handling the Floor Mount Plate and/or the Functional Trainer.
16. Never connect Keiser pneumatic equipment to an air source that is capable of exceeding 120 pounds per square inch (psi)
/ 8.27 bar. Over pressurizing Keiser pneumatic equipment may cause tubing to burst, breakage of equipment, abnormal
operation, or serious injury. Use only clean, dry, regulated compressed air at the rated pressure range of 100–120 psi /
6.89–8.27 bar.
17. It is the responsibility of the facility owner or the owner of the Functional Trainer to instruct users on the safe and proper
operation of the equipment.
CONVENTIONS USED
This Installation Instruction contains the following marks:
WARNING: Indicates a hazardous situation that, if not avoided, could result in death or serious injury.
WEAR SAFETY GLASSES: Safety glasses required during the procedure.
CRUSH HAZARD: Indicates a hazardous situation that, if not avoided, could result in death or serious injury.
HEAVY EQUIPMENT: Indicates help is required during lifting to avoid muscle strain and/or back injury.
IMPORTANT: Indicates information considered critical, but not hazard-related.
If you do not understand these instructions or have doubts about the safety of the installation, assembly, or use of this product,

IMPORTANT SAFETY INFORMATION

CUSTOMER SUPPORT
contact Keiser Customer Support:
1 559 256 8000
service@keiser.com
keiser.com/support
Telephone and Live Chat
Monday—Friday 9 am to 5 pm PST
03

Advertisement

Table of Contents
loading

This manual is also suitable for:

3020xa3020xp3020xs

Table of Contents