5. COOLING

The Easyshrink
15 is featured with two cooling slots equipped with fans. Complementary cooling modules are available.
®
Please refer to Machining Navigator 'Tooling Systems'.

5.1.1. Piloting the cooling fans

5.1.2. Cooling time modification

In order to prevent misuse of this option, the modification of the cooling times is secured and
an access code is required. The access code is given on request and after complete
information about the risks.
Any change of the preset time must be made carefully.
In case of modification without our agreement, Seco Tools AB. cannot be held as responsible
for any damage.
Once you have been provided with the code by your Seco representative, follow this procedure:
1) Press key
.
2) Using keys
and
3) Press key
.
4) Select the first number of the access code by using the arrows
5) Press key
to confirm the first number.
Repeat steps 4 and 5 for the three other digits of the code. If the code is erroneous, you exit from programming. Start the
procedure from scratch.
If the code is correct: the digital displays shows 'COOLING TIME TPS: 15 MIN'.
6) Modify the cooling time by using the arrows on the keypad
7) Press key
to return to previous menu.
8) Press again key
to get out from programming.
The cooling fans can be manually turned on and off from the command keypad:
• Press
Press
Note: when turned on manually, the fans automatically turn off after 2 hours if no shrinking
cycle has been launched.
Alternatively, the cooling fans are automatically triggered at the end of each heating cycles
and will stop after 15 minutes, if no new heating cycle has been launched. Note: during this
15 minutes, the cooling fans cannot be turned off using the button
, select 'PROG COOLING TIME'.
to turn the fans on,
to turn the fans off.
and
.
and
.