6. SAFETY PRECAUTIONS

This shrinking device is only intended for professional use.
Take care to use the correct power supply : the Easyshrink
60 Hz. Power supply for the optional cooling modules is : 1x230V + PE/16A/50-60Hz. Use optional transformers to
accommodate shop electric service from 190 to 510V 3X in USA or CSA for Canadian voltage. Both transformers output
1x230V+PE/16A/50-60Hz for support modules.
By nature on, the Shrinkfit holder becomes very hot. Touching this spot may cause serious burns. Always use gloves
when handling shrink fit holders.
Individuals who carry medical implants are banned from using or working with this device. The carriers of a pacemaker
must refer to the specific note of the pacemaker established on the basis of: NF EN 60601-1-2 (september 2007).
Repairs on the Shrinking devices must be made only by skilled operators. Please contact your local Seco representative.
Only trained and authorized persons are allowed to work on the shrinking devices.
The optional cooling modules are not switched off by the Easyshrink
handling, it's necessary to switch off the power supply using each module's interrupter.

7. RECOMMENDATIONS FOR USE AND MAINTENANCE

Always make sure the holder is cooled down before shrink-fit, or shrink-release.
The holder and the tool must be clean, free from grease and dry before being fitted into the device.
Before starting the shrinking process, please always check if :
o the power supply is sufficient
o the length has been correctly setted, with the correct stop rod
o the correct diameter is selected (mode PRG 1 or PRG 2)
o the correct heat focusing stopper has been setted
o the tool shank is within tolerance h5-h6
o the tool shank is not damaged
Keep the device and its environment clean, to insure a long service life.
The device can only be used for the purposes defined in this operating book. Seco Tools AB. cannot be held as
responsible for casualties caused for any other use.
Maintenance is limited on a regular cleaning of the device and accessories with adapted products.
8. SAFETY FUNCTIONS OF THE EASYSHRINK
The inductor is equipped with a probe to avoid overheating of the holders.
To increase service life of the holders, the electronic of the device has been programmed to allow only one main heating
process, afterwards it automatically cuts off.

9. APPENDICES

9.1.

Technical features

Voltage
Intensity
Frequency
Dimensions L x H x D
Weight
Temperature Air humidity Air pressure
Usage
10 to 40°C
Storage
-20 to 55°C
Transportation
-20 to 70°C
3 x 400 V (+/-10%) + PE
16A
50-60Hz
840 x 880 x 400 mm
50 Kg
10 to 90%
800 to 1013 hPa
(1)
30 to 95%
800 to 1013 hPa
30 to 95%
800 to 1013 hPa
(2)
15 device must be connected on AC 3x400V + PE/ 16A/ 50-
®
15's main interrupter (red power switch). Before any
®
®
15
Prevent condensation and frost
(1)
(3)
Air humidity when the temperature of the device slowly
(2)
increases to 40° or quickly passes from -20 to +30°C
At max. 2000m above the sea level
(3)
22