Verge™ Faucets

Multi-Faucet Wiring

One optional plug-in adapter
splitter kit operates up to four
faucets at one time. Additional
plug-in adapter(s) or splitter kits
are required for installations with
more than four faucets.
AC Adapter Splitter
Kit

Adjusting the Control Module

The control module is set at the factory with the selector switch
in position 5. This provides a 11 second run time.
The 24 hour flush function will activate water flow for a period
of 60 seconds any time there has been no activation within the
past 24 hours. This function is used to help clear stagnant water
from the plumbing system and can provide some measure of
prevention against the formation of bacteria in supply pipes.
Switch position 1 allows a manual
override of the solenoid to allow the
solenoids to flow continuously.
Switch positions 0, 2, and 3 do not apply
to this product.
To adjust the control module to a
different time out period, turn the
A
selector switch to the desired time out
setting (4 through 9 for no flush,
A though F for 24 hours flush) as
indicated on the module label.
8
Connector for
Sensor Cable
9/3/2021
LED Indicator
Selector Switch
Battery Carrier
Power Adapter
Connection
Connection
Bradley • 215-1895 Rev. B: ECO 21-02-022
Installation
S83-440 Timer
Indicators
Red = Disabled
Green = Activated
Diagnostic - See Instructions
0: Test Timer Module I/O
1: Solenoid Open
Custom - See Instructions
2: Push Button Light On/Off
3: Timeout Period
Timeout Setting
4: 4s, no flush
A: 4s, 24hr flush
5: 11s, no flush
B: 11s, 24hr flush
6: 15s, no flush
C: 15s, 24hr flush
7: 30s, no flush
D: 30s, 24hr flush
8: 60s, no flush
E: 60s, 24hr flush
9: 180s, no flush
F: 180s, 24hr flush