Adjust Temperature With Running Water; Test Unit - Bradley Verge Crestt Series Installation Manual

Faucet
Hide thumbs Also See for Verge Crestt Series:
Table of Contents

Advertisement

Installation

Adjust Temperature with Running Water

3
This step only applies for units equipped with a TMA Navigator Mixing Valve.
This valve is NOT factory preset. Upon installation, the temperature of this valve must be checked and
adjusted to ensure delivery of a safe water temperature. Water in excess of 110°F (43°C) may cause scalding.

Test Unit

4
This step only applies for units equipped with a TMA Navigator Mixing Valve.
Shut the hot water inlet off by closing
hot water inlet valve . While the hot
A
water supply is turned off, check
to make sure the cold water flow is
reduced . If the cold water is reduced
properly, reopen the hot water supply .
Bradley • 215-1895 Rev. B: ECO 21-02-022
A
Loosen cap screw about 1/4" (4-6 turns)
and lift up cover (do not remove) .
Using cover, turn cartridge gently until
B
desired water temperature is reached. Do
not turn past stops as this may damage
unit. Push cover down and tighten screw.
DO NOT SKIP THIS STEP!!!
H
Shut the cold water inlet off by closing
B
the cold water inlet valve . While the cold
water supply is off, check to make sure
that the hot water flow has shut down .
9/3/2021
Verge™ Faucets
C
7

Advertisement

Table of Contents
loading