VARIABLE DESCRIPTION
Reset of Absorption system totalizers
Saves the configuration parameters in the PLC memory
Upload of the list of configuration parameters from the memory
Save serial port configuration parameters 1
Upload serial port configuration parameters 1
Save serial port configuration parameters 2
Upload serial port configuration parameters 2
Tank pressure On / Off config. setup
Delta P Absorption System On / Off config. setup
Enable low flow On / Off config. setup
Process simulation On / Off config. setup
Enable On / Off with. vertical tank
Counter cycles per load
Incorrect cycle counter
Cycle injections counter
Number of cycles since the machine was started (it is reset if the system is stopped)
Number of failed injections (if the level inside the burette remains unchanged)
Current time (seconds)
Current time (minutes)
Current time (hours)
Current date (day)
Current date (month)
Current date (year)
Odorant type (1 = TBM; 2 = THT)
1 = Master ; 2 = Slave
Set cycles per block
Maximum load time (s)
Visualization of analogue output 1 on display (1 = instantaneous concentration; 2 = THT-CH4
concentration / hour; 3 = THT-CH4 concentration / day)
Limit set for the reload counter
Correction factor of the ratio set in the PID start up phase
Spare
Spare
Spare
Spare
Spare
Spare
Time set (seconds)
Time set (minutes)
Time set (hours)
Set date (day)
Set date (month)
Set date (year)
Spare
Spare
Spare
Fiscal closing time
Fiscal closing day
Spare
Serial Port 1 - RS485 (0: RS232; 1: RS485)
Serial Port 1 - Codesys Compliant (0: Modbus RTU; 1: SoMachine (when Protocol = 0))
Serial Port 1 - Dataformat (7 bits or 8 bits)
Serial Port 1 - Modbus (0: Modbus RTU o SoMachine (see Codesys Compliant); 1: Modbus ASCII)
Serial Port 1 - addressing Modbus da 0 a 255 (0 per Master; 1 per Slave)
Serial Port 1 - Bit di stop (1: 1 stop bit; 2: 2 stop bit)
Serial Port 1 - Parity (0: Never; 1: Odd; 2: Even)
Serial Port 1 - Time frames (minimum time in ms between 2 frames in Modbus (RTU, ASCII))
Serial Port 1 - ModPol _ Polarization resistance (0: no; 1: yes)
Dosaodor DO200
READ/WRITE
DATA TYPE
R/W
BOOL
R/W
BOOL
R/W
BOOL
R/W
BOOL
R/W
BOOL
R/W
BOOL
R/W
BOOL
R/W
BOOL
R/W
BOOL
R/W
BOOL
R/W
BOOL
R/W
BOOL
R
INT
R
INT
R
INT
R
INT
R
INT
R
UINT
R
UINT
R
UINT
R
UINT
R
UINT
R
UINT
R/W
INT
R/W
INT
R/W
INT
R/W
INT
R/W
INT
R/W
INT
R/W
INT
-
INT
-
INT
-
INT
-
INT
-
INT
-
INT
R/W
INT
R/W
INT
R/W
INT
R/W
INT
R/W
INT
R/W
INT
-
INT
-
INT
-
INT
R/W
INT
R/W
INT
-
INT
R/W
INT
R/W
INT
R/W
INT
R/W
INT
R/W
INT
R/W
INT
R/W
INT
R/W
INT
R/W
INT
ADDRESS (4x holding registers)
Decimal
Bit
7
13
7
14
7
15
8
0
8
1
8
2
8
3
8
4
8
5
8
6
8
7
8
8
15
-
16
-
17
-
18
-
19
-
20
-
21
-
22
-
23
-
24
-
25
-
31
-
32
-
33
-
34
-
35
-
36
-
37
-
38
-
39
-
40
-
41
-
42
-
43
-
44
-
45
-
46
-
47
-
48
-
49
-
50
-
51
-
52
-
53
-
54
-
55
-
56
-
57
-
58
-
59
-
60
-
61
-
62
-
63
-
64
-
57