Specifications
4
I/O configured as output
External connector
Two 2-pin terminal blocks for external devices, for example glass break or fire detectors.
UL: The connector has not been evaluated by UL for burglar or fire alarm use.
Function
DC ground
TAMPER
Function
DC ground
ALARM
Power connector
2-pin terminal block for DC power input. Use a Safety Extra Low Voltage (SELV) compliant limited power source (LPS) with either
a rated output power limited to ≤100 W or a rated output current limited to ≤5 A.
Function
DC ground (GND)
DC input
UL: DC power to be supplied by a UL 294 or UL 603 listed power supply, depending on application, with appropriate ratings.
Pin
Notes
1
2
Digital input – Connect to pin 1 to activate, or leave
floating (unconnected) to deactivate.
Pin
Notes
1
2
Digital input – Connect to pin 1 to activate, or leave
floating (unconnected) to deactivate.
Pin
1
2
Notes
For powering controller when
not using Power over Ethernet.
Note: This pin can only be
used as power in.
28
Specifications
0 V DC
0 to max 30 V DC
Specifications
0 V DC
0 to max 30 V DC
Specifications
0 V DC
12 V DC, max 36 W