Axis A1210 User Manual page 21

Network door controller
Hide thumbs Also See for A1210:
Table of Contents

Advertisement

Specifications
This section contains performance level information required for UL 294 compliance.
Feature
Destructive attack test
Security
Endurance
Standby power
Supported readers
For UL 294, compatibility with the following readers has been verified by UL: AXIS A4020-E, AXIS A4120–E and
HID Signo 20.
Safety instructions
Shall be installed in accordance with Article 725.121 of the National Electrical Code, ANSI/NFPA 70.
The Axis product shall be installed and serviced by a factory trained professional.
The Axis product shall be installed within the protected premises (secured area).
The Axis product shall be mounted indoors. Outdoor use has not been evaluated or approved by UL.
All interconnecting devices shall be UL listed and Class 2 low-voltage power limited.
All power outputs are Class 2 outputs.
All wiring methods shall be performed in accordance with ANSI/NFPA70, local codes and authorities having jurisdiction.
Recommend to use UL recognized grounding wire, a size of 14-16 AWG, yellow/green color. Crimp the cable on the
non-insulated wire pressure ring terminal which is being delivered as a spare part of the product. Important to use proper
crimping tool and techniques to ensure the safety of product and user.
When the Axis product has reached the end of its useful life, dispose of it according to local laws and regulations. The
product should not be disposed of together with household or commercial waste.
Do not connect the Axis product to a receptacle controlled by a switch.
Battery
-
The 3.0 V lithium battery used by the Axis product is a UL recognized component. (Type: BR2032, diameter:
20 mm (0.78 in), manufacturers: Power Glory (Omnergy)). The following battery type is also a UL recognized
component: Type CR2032.
-
Users shall not replace the battery. If the battery needs replacing, it must be done by a trained technician only.
-
Used batteries shall be disposed of according to local laws and regulations, which may vary from state to state.
Waste BR/CR lithium cells are neither listed nor exempted from the USEPA hazardous waste regulations. Waste
lithium batteries can be considered reactive hazardous waste if there is a significant amount of unreacted, or
unconsumed lithium remaining. For information about how to dispose of used lithium batteries, contact
your local authority for waste disposal.
Specifications
Operating conditions
Level
I
I
IV
I
21