Axis A1210 User Manual page 22

Network door controller
Hide thumbs Also See for A1210:
Table of Contents

Advertisement

Specifications
Normal use (not evaluated by UL)
UL 294
Wiring requirements
-
UL listed or R/C AWM wires that have a conductor gauge range of AWG 22–14 shall be used.
-
The minimum conductor gauge for connection between the power sourcing equipment (PSE) or power injector
and the powered device (PD) is 26 AWG.
-
Minimum PoE category 5e, shielded cable, required for PoE.
-
This product is not intended for outside wiring as covered by Article 800 in the National Electrical Code, NFPA 70.
Connectors
-
Power Connector – For UL security applications, the product shall be powered by a UL 294 or UL 603 listed
Class 2 low-voltage power SELV and limited power supply with appropriate ratings.
-
External power to relays - If the relays are connected to an external power source this must be UL 294 listed
Class 2 low-voltage power SELV and limited power supply.
-
Network Connector – Standard Ethernet wiring. Evaluated by UL when powered from AXIS T8133 Midspan 30
W 1-port in PoE Mode B (alternative A).
-
Battery input is for connection to a listed UPS and has not been evaluated by UL to UL 294.
-
Supervised inputs were not evaluated by UL for burglar use.
System considerations
-
Monitoring software was not evaluated by UL, and is for supplemental use.
Maintenance instructions
-
For maintenance instructions and for information about how to configure the Axis product, see the User Manual.
Further information
-
Card formats verified by UL: ISO Cards Mifare 1K, 32 bits.
Power
-
Power in: 10.5–28 V DC, max 36 W, max 2.4 A at 10.5 V, max 0.9 A at 28 V.
Power over Ethernet (PoE) IEEE 802.3at Type 2 Class 4, max 340 mA. 12 V battery as
backup.
-
Relay: 2x relay NO/NC, max 2 A DC
-
Power out lock: 2x 12/24 V DC,
With PoE+: at 12 V, 11 W, at 24 V, 10 W
With DC in: at 12 V, 22.5 W, at 24 V, 18 W
-
Power out reader: 12 V DC, max 6 W
-
Auxiliary DC output: 1x 12 V DC output, max 200 mA
-
Total power budget for peripheral devices (locks, readers etc.): 2100 mA at 12 V if powered by DC, 1300 mA at
12 V if powered by PoE Class 4
I/O interface – I/O functionality
-40 °C to 55 °C (-40 °F to 131 °F)
Humidity 20–85% RH (non-condensing)
0 °C to 55 °C (32 °F to 131 °F), maximum humidity 85%.
Intended for use in UL listed enclosure with tamper switch.