Emc And Environmental Type Tests - Siemens SIMATIC NET RUGGEDCOM M969F Installation Manual

Rugged ethernet switches
Table of Contents

Advertisement

MIL-STD 901D
MIL-STD-1275B
MIL-STD-1399
7.3

EMC and Environmental Type Tests

The RUGGEDCOM M969F has passed the following EMC and environmental tests.
IEC 61850-3 Type Tests
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-29
IEC 61000-4-11
IEC 61000-4-12
RUGGEDCOM M969F
Installation Manual, 11/2022, C79000-G8976-1349-04
Test
Test
Description
ESD
Radiated RFI
Burst (Fast
Transient)
Surge
Induced
(Conducted) RFI
Magnetic Field
Voltage Dips
& Interrupts
Damped
Oscillatory
7.3 EMC and Environmental Type Tests
High Impact Shock Test
Power Quality
DC Magnetic Field Testing Section 070 Part 1
Enclosure
Contact
Enclosure Air
Enclosure ports
Signal ports
DC Power ports
AC Power ports
Earth
ground ports
Signal ports
DC Power ports
AC Power ports
Signal ports
DC Power ports
AC Power ports
Earth
ground ports
Enclosure ports
DC Power ports
30% for 0.1 s, 60% for
0.1 s, 100% for 0.05 s
AC Power ports
100% for 50 periods
Signal ports
2.5 kV common, 1 kV
differential mode @ 1MHz
DC Power ports
2.5 kV common, 1 kV
differential mode @ 1MHz
Certification
Description
Test Levels
± 8 kV
± 15 kV
20 V/m
± 4 kV @ 2.5 kHz
± 4 kV
± 4 kV
± 4 kV
± 4 kV line-to-earth,
± 2 kV line-to-line
± 2 kV line-to-earth,
± 1 kV line-to-line
± 4 kV line-to-earth,
± 2 kV line-to-line
10V
10 V
10 V
10 V
40 A/m continuous,
1000 A/m for 1 s
30% for 1 period,
60% for 50 periods
100% for 5 periods,
2
Severity
Levels
4
4
x
x
4
4
4
4
3
4
3
3
3
3
3
3
43