In the case of malfunctions of the PKL proceed as follows:
Malfunctions
and causes
Malfunction
Does not function
Does not function and
has leakage at top
Does not function and
has leakage on mount-
ing surface
Does not function with
ST kit
Impact weak
Possible causes
Mounting surface not flat, loss
of pressure via O-ring
Malfunction of valve and con-
trol
Compressed air supply
Wear of seals
General wear (Housing and
membrane)
PKL incorrectly mounted
Mounting surface not flat
Operating pressure insufficient
Compressed air supply
Contamination of control valve
Contamination of silencer
Wear, leakage
Corrective actions
Establish ±0.1 mm flatness on
mounting surface.
Check PKL without valve and
control. Check valve and con-
trol, and replace if necessary.
Check pressure and increase
if necessary.
Check valve connection. Re-
place valve, if necessary.
Check seals of impact piston,
replace if necessary.
Replace affected parts and
seals.
Tighten fastening screws and
replace, if necessary.
Establish ±0.1 mm flatness on
mounting surface.
Check O-ring. Insert O-ring in
groove, replace if damaged.
Check PKL model. Check
pressure and increase if nec-
essary.
Check pressure and increase
if necessary.
Clean control valve or replace,
if necessary.
Clean silencer.
Replace seals.