Maintenance And Servicing - NetterVibration PKL Series Operating Instructions Manual

Netter pneumatic impactors
Table of Contents

Advertisement

8

Maintenance and servicing

Observe the safety instructions in Ch. Safety, from page 5 on.
Maintenance of the PKL must be carried out as follows:
Maintenance
plan
Interval
After one hour of opera-
tion after initial commis-
sioning
Monthly
At the latest after a total
of 500,000 strokes
In the course of its service life, a film can form due to wear, which impairs
Cleaning
functioning. If loss in performance or standstill is noticed, proceed as fol-
lows:
1.
2.
3.
4.
Special tools are needed for inserting piston, guide rings and piston seal
(available on request).
Maintenance
The maintenance intervals depend essentially on the service life and how
intervals
clean the drive medium is.
Unfiltered compressed air leads to high wear, silencer clogging or com-
plete failure of the PKL.
Implementa-
Maintenance, repair and general overhaul of the PKL may alternatively be
tion by Netter
performed by
22
Action
Check fastening screws.
Check hose screw connections and hose connections and
retighten, if necessary.
Check fastening screws.
Check fastening kit NBS.
Check hose screw connections and hose connections and
retighten, if necessary.
Check hose supply connections for permeability and kinks. If
necessary, clean and remove kinks.
Check the function of the silencer.
Check impact effect.
For installation with mist lubricator:
Ensure that mist lubricator operates according to regulations.
Refill oil.
Empty the filter of the maintenance unit if necessary, clean
the filter insert (wash out) and replace if necessary.
Carry out the general overhaul, in which all wear parts must
be replaced.
Remove piston.
Clean piston.
Replace guide ring and piston seal, if necessary.
Reinsert piston.
Netter
Vibration.
Maintenance and servicing

Hide quick links: