Troubleshooting - NetterVibration VAC Series Assembly Instructions Manual

Hide thumbs Also See for VAC Series:
Table of Contents

Advertisement

Troubleshooting

9
Troubleshooting
In the case of malfunctions of the VAC proceed as follows:
Malfunctions
and causes
Malfunction
VAC does
not gener-
ate vacuum
VAC slides
when vi-
brated
Possible causes
Corrective actions
Air supply insuffi-
Check pressure before VAC and set to 2 to 6 bar.
cient
Hose connections
Check the hose connection assembly.
not correctly as-
sembled
Lines kinked
Lay lines without kinking.
Cross-section of
Increase cross-section of supply line.
supply line insuffi-
cient
Silencer clogged
Clean or replace silencer.
Vacuum nozzle
Clean vacuum nozzle (let clean; see page 24,
clogged
"maintenance plan").
Mounting surface
VAC is not suitable for this application.
permeable to air or
rough
Air supply insuffi-
Check pressure before VAC and set to 2 to 6 bar.
cient
Lines kinked
Lay lines without kinking.
Silencer clogged
Clean or replace silencer.
Vacuum nozzle
Clean vacuum nozzle (let clean; see page 24,
clogged
"maintenance plan").
Mounting surface
VAC is not suitable for this application.
permeable to air
Mounting surface
Remove relevant layers.
oily, greasy or
moist
Suction cups worn
Replace aged, brittle suction cups.
Subsurface rein-
Put VAC on elastic surface between reinforcements
forced
(membrane effect).
(bounce impacts)
Vibrational fre-
Set frequency with a non-return throttle valve.
quency too high