Maintenance And Servicing - NetterVibration NTP Series Operating Instructions Manual

Pneumatic linear vibrators
Table of Contents

Advertisement

Maintenance and servicing

8
Maintenance and servicing
Observe the safety instructions in Ch. Safety, from page 5 on.
If necessary clean the surface of the NTP with a moist cloth to remove
Cleaning
dust deposits.
To clean the NTP with pressurised water, proceed as follows:
1.
2.
3.
Maintenance
Maintenance of the NTP must be carried out as follows:
plan
Interval
After one hour of opera-
tion after initial commis-
sioning
Monthly
* Observe the recommended tightening torques (see Ch. Technical data, from page 7 on).
Maintenance
The maintenance intervals depend essentially on the service life and how
intervals
clean the drive medium is.
Unfiltered compressed air leads to high wear, silencer clogging or com-
plete failure of the NTP.
Loss of per-
If you notice loss of performance or standstill of the NTP then have the
formance
NTP checked at
Close the supply air and exhaust air openings.
Clean the NTP externally with pressurised water.
Activate the NTP briefly.
Action
Check fastening screws.*
Check hose screw connections and hose fittings, retighten if
necessary.
Check fastening screws.*
Check hose screw connections and hose fittings, retighten if
necessary.
Check hose supply connections for permeability and kinks. If
necessary, clean and remove kinks.
Check the function of the silencer. Clean silencer.
Check the function of the NTP.
Check the function of the mist lubricator (Content decreases?
Number of drops/min?). Refill oil (except for the NTP L).
Empty the filter of the maintenance unit, if necessary, clean
the filter insert (wash out) and replace, if necessary.
Netter
Vibration.
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ntp 18Ntp 32Ntp 25Ntp 48

Table of Contents