Ricoh Aficio MP C3001 Service Manual page 419

Hide thumbs Also See for Aficio MP C3001:
Table of Contents

Advertisement

[Temperature/Humidity: Display]
2241
Displays the environment temperature and humidity.
001 Temperature
002 Relative Humidity
003 Absolute Humidity
[Environmental Correction: Transfer]
2302
Environmental Correction: Image Transfer Belt Unit
Current Environmental
001
Display
002 Forced Setting
Absolute Humidity:
003
Threshold 1
Absolute Humidity:
004
Threshold 2
SM
-
[–1280 to 1270 / - / 0.1deg/step]
-
[0 to 1000 / - / 0.1 %RH/step]
-
[0 to 100 / - / 0.01 g/m
-
Displays the current environment condition.
Sets the environment condition manually.
[0 to 6 / 0 / 1 /step]
0: Automatic environment control
1: LL (Low temperature/ Low humidity)
*ENG
2: ML (Middle temperature/ Low humidity)
3: MM (Middle temperature/ Middle
humidity)
4: MH (Middle temperature/ High humidity)
5: HH (High temperature/ High humidity)
Adjusts the threshold value between LL and
*ENG
ML.
[0 to 100 / 4 / 0.01 g/m
Adjusts the threshold value between ML
*ENG
and MM.
[0 to 100 / 8 / 0.01 g/m
5-69
Main SP Tables-2
3
/step]
3
/step]
3
/step]