Ricoh Aficio MP C3001 Service Manual page 906

Hide thumbs Also See for Aficio MP C3001:
Table of Contents

Advertisement

IH Inverter
Rating
Fuse
115V
FU1
15A/125V
FU2
FU3
FU4
1A/250V
For continued protection against risk of fire, replace only with same type and rating
of fuse.
D086/D087
Symptom when turning on the main switch
220V - 240V
15V power to the IH coil unit is not supplied.
8A/250V
SC689 occurs.
115°C
No response
115°C
No response
15V power to the IH coil unit is not supplied.
SC689 occurs.