4.6.2 LD SAFETY SWITCH

A relay on the PSU ensures technician and user safety. It also prevents the laser beam from
turning on during servicing. This relay turns off when the front cover, upper left cover, or right
door is opened. At this time it cuts the power (+5V) supplied to the LD board for each color
through the BICU.
Two safety switches are turned on or off by the front door or right door, and this opens the
relay.
LD Driver: Precise Pulse Modulation ASIC on C-MOS technology
LDB: LD Drive Board (included in the LD Unit)

Error Messages

Along with other switches, the LD safety switches help show error messages related to
external covers. When one or more covers are open, the messages, "Cover is open." and
"Close the indicated cover," show with a diagram. The diagram shows which cover is open.
D086/D087