Home Screen - PROALL Mobile Mixer Operator's Manual

Mobile mixer
Table of Contents

Advertisement

1.02 HOME SCREEN

1
8
1. Auger speed percentage. The auger speed is adjustable from 0-100%. Speed setting is dependant on the
materials used and the production rates required. For gunite, this is typically set around 60-80%.
2. With gate height verification sensor:
The center number is the actual gate height position.
The small number in blue is the mix design gate position required.
Without gate height verification sensor:
The large number is the mix design gate position.
3. Belt speed percentage. The belt speed is adjustable from 0-100%. Speed setting is dependant on the gunite pump
production rate required.
4. MENU screen button. Pressing this will take the user to the main menu navigation screen.
5. Cement meter auger RPM. This gauge is used for reference to ensure the cement auger is on and turning.
6. Production rate/belt RPM gauge. Used to verify production speeds and belt RPM settings.
7. Hydraulic oil pressure. This is a reference for the load mixer and can be used for diagnostic purposes.
8. Selected mix design number. The mix number of the selected design on the Mix Select screen.
9. Total concrete volume currently produced.
10. Selected mix design strength.
Operator's Manual, Ranger Gunite r1.0
2
5
9
3
6
4
7
10
pg. 5