1.14 ALARM SYMBOLS & TROUBLESHOOTING
Alarm messages, when activated, show on the screen in the form of a triangle with a brief description of the alarm.
Depending on the alarm priority the alarm message may stay on the screen until the alarm is acknowledged by the
operator. Lower priority alarms will show a blinking alarm message. Alarms can be removed by pressing Fault Reset in the
Mixer Control screen or using one of the over-rides. Below is a summary of all alarms that are possible on the display.
Emergency Stop (E-Stop) pressed on the wireless remote (RED button). The mixer will stop when this
alarm is activated. The alarm cannot be removed until the wireless E-Stop is reset.
The radio remote has lost the link to the receiver. This is typically caused when batteries need to be
replaced or the remote is too far away from the receiver. If this alarm is activated the machine will stop.
The operator must acknowledge the alarm by pressing the belt button on the mixer control knob (#5).
The machine can then be run without the wireless.
Auger jam alarm. The mix auger pressure has reached the pressure limit as entered in the mixer settings
screen and the belt stops. Check to see why pressure max has been reached (auger jammed) or increase
pressure limit if need be.