Summary of Contents for Leica NA2

  • Page 1 Leica NA2/NAK2 User Manual English Version 2.0 GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 2 Automatic level Congratulations on your purchase of a NA2/NAK2 automatic level. This manual contains important safety directions as well as instructions for setting up the product and operating it. Refer to "Safety Directions" for further information. Read carefully through the User Manual before setting up the product.
  • Page 3 The model and the serial number of your product are indicated on the housing. Enter the model and serial number in your manual and always refer to this information when you need to contact your agency or Leica Geosystems authorized service workshop. Type: Serial no.:...
  • Page 4 Important paragraphs which must be adhered to in practice as they enable the product to be used in a technically correct and efficient manner. Symbols used in this manual NA2/NAK2-2.0.0en GlobalTestSupply www. .com Find Quality Products Online at:...
  • Page 5: Table Of Contents

    Measuring ................14 Checking and adjusting ........... 20 Care and Storage .............. 22 Safety Directions .............. 25 Accessories ............... 32 Technical Data ..............34 Index ................... 35 View of chapters NA2/NAK2-2.0.0en GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 6 Accessories ..........32 Levelled stakeout ........18 Technical Data ......... 34 Precise levelling ........19 Index ............35 Checking and adjusting ......20 Tripod ............20 Circular level ..........20 Contents NA2/NAK2-2.0.0en GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 7: Introduction

    Introduction Special features The NA2/NAK2 universal • Easy operation, quick to automatic level meets all learn! precision, convenience and • Robust and reliable. reliability requirements. It‘s innovative technology will • High setting accuracy. make daily surveying jobs • Endless drive.
  • Page 8: Important Parts

    Rapid/fine focussing knob Objective housing Push-button for compen- sator control Footscrew 10 Milled rim, for Hz-circle setting (NAK2 only) Circular level 12 Base plate 13 Endless horizontal drive (both sides) Introduction NA2/NAK2-2.0.0en GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 9: Technical Terms And Abbreviations

    The push button gives the (V). Additional points relating to pendulum a slight tap to check the A are measured as intermediate functioning of the compensator. sight (S). Introduction NA2/NAK2-2.0.0en GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 10: Measurement Preparation

    Measurement preparation Case contents Remove NA2/NAK2 level from the case and check that all components are present. Level User Manual Allen key/Adjusting pins Protective cover & sun shade Measurement preparation NA2/NAK2-2.0.0en GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 11: Setting Up The Tripod

    When pressing the legs into • Use the tripod only for the ground note that the force surveying jobs. must be applied along the legs. Measurement preparation NA2/NAK2-2.0.0en GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 12: Levelling Up

    2. Turn footscrews of tribrach directions until bubble is in into centre position. the centre (on the imaginary "T"). 3. Centre circular level by turning the foot screws. Measurement preparation NA2/NAK2-2.0.0en GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 13: Focusing Telescope

    3. Tighten central fixing screw. other. Measurement preparation NA2/NAK2-2.0.0en GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 14: Measuring

    8. Read off height H at the the instrument adjust to focusing knob. horizontal reticule hair. the ambient temperature Example above: H=1.143 (approximately 2 minutes per ºC of temperature difference). Measuring NA2/NAK2-2.0.0en GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 15: Distance Measuring

    “0” or any represents 10’. The minutes are Result: desired reading. read from the top scale line to Distance d = 100 x L the circle graduation line. Measuring NA2/NAK2-2.0.0en GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 16: Line Levelling

    5. Setup level at I , aim at staff -0.981 651.902 at the changepoint 2 and Procedure: ∆H= read backsight and take 1. Setup instrument at I Sum +6.516 -4.714 down. +1.802 Measuring NA2/NAK2-2.0.0en GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 17: Area Levelling

    6. Repeat steps 4 and 5 for read the staff on a stable -2.50 591.70 additional intermediate intermediate point (reading must points. -2.30 591.90 remain the same). ⊗ =Instrument horizon Measuring NA2/NAK2-2.0.0en GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 18: Levelling Total Station Measuring

    L (see chapter carried out during area levelling. "Distance measuring") and the Hz-angle. 2. Transfer measured value into the map - points are determined by position and height. Measuring NA2/NAK2-2.0.0en GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 19: Precise Levelling

    3. Centimetres are read from can cause errors. the staff and millimetres from the micrometer scale. In sunny weather an 4. Leica invar staffs have two umbrella should be used sets of graduations. These to shelter the instrument to are read alternatively...
  • Page 20: Checking And Adjusting

    2. Tighten the articulated joints adjusted (see point 4). telescope direction. on the tripod head (1) just enough to keep the tripod legs open when you lift it off the ground. Checking and adjusting NA2/NAK2-2.0.0en GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 21: Checking And Adjusting Of The Line-Of-Sight

    4. Repeat the checking 7. Find nominal reading A2; graduation. procedure. Reading A1 - B1 + B2 Checking and adjusting NA2/NAK2-2.0.0en GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 22: Care And Storage

    Care and Storage Transport In the field When transporting or shipping the equipment always use the original Leica Geosystems packaging (transport case and shipping cardboard). After a longer period of storage or transport of your product always check the field adjustment parameters...
  • Page 23: Inside Vehicle

    Leica if the equipment is inside a Always carry the product in its Geosystems packaging, vehicle.
  • Page 24: Cleaning

    If completely dry. necessary, moisten the cloth with water or pure alcohol. When using the instrument in the field always close the transport case. Care and Storage NA2/NAK2-2.0.0en GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 25: Safety Directions

    • Modification or conversion of circle (only NAK2 model) the product • Use after misappropriation • Use of products with obviously recognizable damages or defects Safety Directions NA2/NAK2-2.0.0en GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 26: Limits Of Use

    Adverse use can lead to Suitable for use in an the prior explicit approval of injury, malfunction and atmosphere appropriate for Leica Geosystems damage. permanent human habitation: • Aiming directly into the sun It is the task of the person not suitable for use in aggressi- •...
  • Page 27: Responsibilities

    The person in charge of the product Leica Geosystems AG, CH- Geosystems accessories: has the following duties: 9435 Heerbrugg, hereinafter The manufacturers of non Leica • To understand the safety referred to as Leica Geosystems accessories for the instructions on the product and...
  • Page 28: Hazards Of Use

    Safety Directions NA2/NAK2-2.0.0en GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 29 Always ensure that the survey Do not point the product directly site is adequately secured. at the sun. Adhere to the regulations governing safety and accident prevention and road traffic. Safety Directions NA2/NAK2-2.0.0en GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 30 (person at the fixing screw. If the screw is staff). loosened always remove the product immediately from the tripod. Safety Directions NA2/NAK2-2.0.0en GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 31 Safety Directions NA2/NAK2-2.0.0en GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 32: Accessories

    Housing of parallel plate Knob for locking GPM3 in position For precise levelling the GPM3 is fitted onto the NA2 telescope objective and locked in position with the knob (4). By turning the micrometer knob the parallel-sided glass plate is tilted, thereby causing the line of sight to be raised or lowered.
  • Page 33 With the can be fitted to the objective. autocollimation eyepiece the Measuring range is 1.8 to 0.9m. NA2 can be used for alignment purposes in the laboratory and GEB60 Eyepiece lamp with industry. cable (Art.
  • Page 34: Technical Data

    10 mm • Multiplication factor • Interval 0.1 mm • Additive constant • Estimation 0.01 mm Compensator: • Working range ± 30‘ • Setting accuracy (stand. dev.) 0.3“ Technical Data NA2/NAK2-2.0.0en GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 35: Index

    Distance line ..........15 Packaging ............ 23 Plumb bob ............ 13 Plummet ............13 Electrical installations ........28 Precise levelling ........19, 32 Environment ..........26 Eyepiece ..........13, 33 Index NA2/NAK2-2.0.0en GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 36 Stakeout ............18 Storage ..........22, 24 Storing ............23 Target distances .......... 16 Total station measuring ....... 18 Transport ............22 Transport case ........22, 24 Tripod ............20 Index NA2/NAK2-2.0.0en GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 37 Our commitment to total customer being equipped with a quality system satisfaction. which meets the International Standards of Quality Management Ask your local Leica Geosystems and Quality Systems (ISO standard agent for more information about 9001) and Environmental our TQM program.

This manual is also suitable for:

Nak27640110691724