Evco Vcolor 739 M Manual

Evco Vcolor 739 M Manual

Electronic controllers with 5” or 7” tft graphic display for multifunctional ice cream and patisserie machines
Hide thumbs Also See for Vcolor 739 M:
Table of Contents

Advertisement

Quick Links

Vcolor 739 M/L
Electronic controllers with 5" or 7" TFT graphic display
for multifunctional ice cream and patisserie machines
WARNING
Make sure you read and fully
understand the manual before
using this device.
Non-observance of these
instructions may result in death
or serious injury.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Vcolor 739 M and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Evco Vcolor 739 M

  • Page 1 Vcolor 739 M/L Electronic controllers with 5” or 7” TFT graphic display for multifunctional ice cream and patisserie machines WARNING Make sure you read and fully understand the manual before using this device. Non-observance of these instructions may result in death...
  • Page 2: Table Of Contents

    3.1 Before you start ...........................15 3.2 Information concerning installation and the surrounding environment ........15 3.3 Dimensions for models mounted with protruding front panel ............16 3.3.1 Vcolor 739 M user interface ........................16 3.3.2 Vcolor 739 L user interface........................16 3.3.3 Base board ..............................17 3.4 Flush mounting model dimensions .....................18...
  • Page 3 CONTENTS 4.2.2 Vcolor 739 L user interface........................26 4.2.3 Vcolor 739 M/L base board ........................27 4.3 Connection example ..........................28 5. USER INTERFACE .......................... 29 5.1 Interface ...............................30 5.2 Icons ..............................30 5.3 Touch keys ............................30 5.4 Function keys/icons ..........................30 5.5 Using the controller ..........................31 5.5.1 Controller ON/OFF ............................31...
  • Page 4 9.1 Description of columns in the Table of Parameters .................58 9.2  Table of configuration parameters for Vcolor 739 ................58 9.3  Table of Inverter configuration parameters..................61 10. DIAGNOSTICS ..........................62 10.1 Introduction ............................63 10.2 Table of Vcolor 739 alarms .......................63 10.3 Table of inverter alarms ........................64 144V739E4.00 · Vcolor 739 M/L | 4 | 12/2022...
  • Page 5: Important Information

    IMPORTANT INFORMATION Liability and residual risks EVCO assumes no liability for any damage caused by the following (by way of example; this is not an exhaustive list): •  I nstallation/useforpurposesotherthanthosespecifiedand,inparticular,notadheringtothesafetyprovisionssetout by current regulations in the country in which the product is installed and/or contained in this manual;...
  • Page 6: Important Safety Information

    NOTICE indicates a situation not related to physical injuries but which,ifnotavoided,could damage the equipment. NOTE: t hemaintenance,repair,installationanduseofelectricalequipmentmustonlybeentrustedtoqualifiedpersonnel. QUALIFIED PERSONNEL Only suitably trained and experienced personnel capable of understanding the content of this manual and all documentation regardingtheproductareauthorisedtoworkonandwiththisequipment.Furthermore,thepersonnelmusthavecompleted coursesinsafetyandmustbeabletorecogniseandpreventtheimplieddangers.Thepersonnelmusthavesuitabletraining, knowledgeandexperienceatatechnicallevel,andbecapableofanticipatinganddetectingpotentialriskscausedbyusing theproduct,aswellaschangingthesettingsandmodifyingthemechanical,electricandelectronicequipmentfortheentire systeminwhichtheproductisused.Allpersonnelworkingonandwiththeproductmustbeentirelyfamiliarwiththerelevant standardsanddirectives,aswellassafetyregulations. 144V739E4.00 · Vcolor 739 M/L | 6 | 12/2022...
  • Page 7: Safety Information Relating To The Product

    • Do not use this equipment for machine functions that are critical to safety. • Donotdisassemble,repairormodifytheequipment. • Do not connect wires to unused terminalsand/orterminalsmarkedwiththetext“Noconnection”(“N.C.”). 144V739E4.00 · Vcolor 739 M/L | 7 | 12/2022...
  • Page 8: Introduction

    1. INTRODUCTION Chapter content This chapter contains the following information: Subject Page Description Available models Features Accessories 144V739E4.00 · Vcolor 739 M/L | 8 | 12/2022...
  • Page 9: Description

    1.1 DESCRIPTION Vcolor 739 M/L controllers are the EVCO solution for complete management of multifunctional ice cream and patisserie machines,andcanbeusedto: • Knead; • Cook; • Pasteurise; • Whisk; • Etc. Vcolor 739 M/L controllers consist of: • Built-in base power board;...
  • Page 10: Accessories

    1.4 ACCESSORIES The Vcolor 739 M/L range is supplemented with the following accessories: Type Description Pt1000 temperature probes EVIF25SWX EVlinkingRS-485/Wi-Fimodule CJAV55 Kit for removable terminals on the power base ECTSFD004 Safetytransformer230Vac/12Vac,20VA 0812000002 USBplugtypeAIP65 EVUSB4096M USBflashdrive4096MB 0810500018 USB2.0cable,2m,M/M 0810500020 USB2.0cable,0.5m,M/M EVIF20SUXI NonoptoisolatedRS-485/USBserialinterface 144V739E4.00 ·...
  • Page 11: Technical Data

    2. TECHNICAL DATA Chapter content This chapter contains the following information: Subject Page Introduction Technical specifications I/O specifications 144V739E4.00 · Vcolor 739 M/L | 11 | 12/2022...
  • Page 12: Introduction

    They must be installed in casing or another location designated on the basis of specific environmental conditions andinordertominimisetheriskofinvoluntarycontactwithhazardousvoltage.Usemetalcasingtoimproveimmunitytothe electromagnetic fields of the Vcolor 739 M/L system. This equipment satisfies the EC requirements as indicated in the tables below. WARNING MALFUNCTIONING OF THE EQUIPMENT Do not exceed any of the nominal values specified in this section.
  • Page 13: I/O Specifications

    Out13 Condenser fan SPST Resistive Out14 Technical room fans SPST Resistive Out15 Cooling solenoid valve SPST Resistive 2.3.2 User interface Type Description Serialports: 1xRS-485fieldbuscommunicationserialportforconnection with base board 1xRS-485RTUSLAVEcommunicationserialportfor connectionwithEPoCAorthird-partymonitoringsystem 1xUSB2.0typeAserialport(operationguaranteedwith EVUSB4096M) 144V739E4.00 · Vcolor 739 M/L | 13 | 12/2022...
  • Page 14: Mechanical Assembly

    Before you start Information concerning installation and the surrounding environment Dimensions for models mounted with protruding front panel Flush mounting model dimensions Vcolor 739 installation Base power board installation Minimum installation distances 144V739E4.00 · Vcolor 739 M/L | 14 | 12/2022...
  • Page 15: Before You Start

    • Do not use this equipment for machine functions that are critical to safety. • Donotdisassemble,repairormodifytheequipment. • Do not connect wires to unused terminalsand/orterminalsmarkedwiththetext“Noconnection”(“N.C.”). 144V739E4.00 · Vcolor 739 M/L | 15 | 12/2022...
  • Page 16: Dimensions For Models Mounted With Protruding Front Panel

    3.3 DIMENSIONS FOR MODELS MOUNTED WITH PROTRUDING FRONT PANEL 3.3.1 Vcolor 739 M user interface mm (in.) Fig. 1. Protruding front panel Vcolor 739 M user interface dimensions 3.3.2 Vcolor 739 L user interface mm (in.) 47 (1.85) Fig. 2.
  • Page 17: Base Board

    3.3.3 Base board mm (in.) 110 (4.33) 131 (5.16) Ø 4 (0.157) 249 (9.80) (1.30) Fig. 3. Base board dimensions 144V739E4.00 · Vcolor 739 M/L | 17 | 12/2022...
  • Page 18: Flush Mounting Model Dimensions

    3.4 FLUSH MOUNTING MODEL DIMENSIONS 3.4.1 Vcolor 739 M user interface 35 (1.38) 1.9 (0.07) Fig. 4. Flush mounting Vcolor 739 M user interface dimensions 3.4.2 Vcolor 739 L user interface mm (in.) 50 (1.97) 3 (0.12) Fig. 5. Flush mounting Vcolor 739 L user interface dimensions 144V739E4.00 ·...
  • Page 19: Vcolor 739 Installation

    Vcolor 739 M Vcolor 739 L user interface user interface mm (in.) 130 (5.11) 178.2 (7.01) Fig. 6. Installing Vcolor 739 M user interface with protruding front panel Panel thickness Thispanelthicknessdependingonthematerialusedtomakeit: Material Thickness (X) [mm (in.)] Metal 0.8...1.5 (0.03...0.06) Plastic 0.8...3.4 (0.03...0.13)
  • Page 20: Flush Mounting From The Rear Of The Panel

    142.25 (5.60) Vcolor 739 L mm (in.) R8.1 190 (7.48) Installation result Fig. 7. Flush mounting Vcolor 739 M/L user interface from the rear of the panel Panel thickness Thethicknessofthepanelusedforflushinstallationfromthebackofapaneldependingonthemodel: Model Thickness (X) [mm (in.)] Vcolor 739 M 1.9 (0.07) Vcolor 739 L 3.0 (0.12)
  • Page 21 Captive screw hole spacing for Vcolor 739 M user interface Themetalpanelusedforflushinstallationfromthebackofapanelshouldtakeaccountofthecaptivescrewstobefittedtoit,in accordance with the following measurements: 78 (3.07) 156 (6.15) Fig. 8. Captive screw hole spacing measurements for Vcolor 739 M Captive screw hole spacing for Vcolor 739 L user interface...
  • Page 22: Base Power Board Installation

    (in.) 40 (1.57) 40 (1.57) Fig. 10. Vcolor 739 M/L user interface minimum installation distances 3.7.2 Base board Observe the minimum distance of 40 mm (1.57 in.) on each side when installing the base board. 144V739E4.00 · Vcolor 739 M/L...
  • Page 23: Electrical Connections

    4. ELECTRICAL CONNECTIONS Chapter content This chapter contains the following information: Subject Page Wiring best practices Wiring diagrams Connection example 144V739E4.00 · Vcolor 739 M/L | 23 | 12/2022...
  • Page 24: Wiring Best Practices

    • Do not use this equipment for machine functions that are critical to safety. • Donotdisassemble,repairormodifytheequipment. • Donotconnectwirestounusedterminalsand/orterminalsmarkedwiththetext“Noconnection”(“N.C.”). 144V739E4.00 · Vcolor 739 M/L | 24 | 12/2022...
  • Page 25: Guidelines For Screw Terminals

    1=RS-485 BUS LT RS-485 BUS (2) 2=RS-485 RTU LT RS-485 RTU (1) TO BASE BOARD Fig. 13. Vcolor 739 M user interface wiring diagram TERMINALS 30...32 RS-485 RTUSlaveserialportconnection ServiceUSBport(forgraphiccustomization) 34...36 RS-485 fieldbus serial port connection 1=ActivationofRS-485 BUS serial port termination resistor...
  • Page 26: Vcolor 739 L User Interface

    DP1 RS-485 RTU serial port termination resistor ON/OFF 33-36 12 Vac/dc power supply input DP2 RS-485 fieldbus serial port termination resistor ON/OFF 34...36 RS-485 fieldbus serial port connection USB ServiceUSBport(forgraphiccustomization) (1) = RS-485communicationserialportwithEVlinkingWi-Fi; (2) = RS-485communicationserialportwith base board. 144V739E4.00 · Vcolor 739 M/L | 26 | 12/2022...
  • Page 27: Vcolor 739 M/L Base Board

    30 29 28 27 26 25 20 19 18 17 16 15 14 13 12 11 10 9 8 7 Fig. 15. Vcolor 739 M/L base board wiring diagram TERMINALS Power supply input 30-28 Digital output Out14 (Technical room fans) OUT112VdcoutputforexternalSSRrelay(heating...
  • Page 28: Connection Example

    4.3 CONNECTION EXAMPLE Fan power supply 12 V RS-485 + RS-485 - RS-485 GND Power supply 144V739E4.00 · Vcolor 739 M/L | 28 | 12/2022...
  • Page 29: User Interface

    Data log View alarm list Change Date and Time Machine info Change language In/out status Output test (EXPERT/OEM ONLY) Internal data reset (EXPERT/OEM ONLY) Parameter management (EXPERT/OEM ONLY) PID setup (OEM ONLY) 144V739E4.00 · Vcolor 739 M/L | 29 | 12/2022...
  • Page 30: Interface

    Used to navigate through screens within the menus At the bottom of the display Used to navigate through screens within the menus 5.4 FUNCTION KEYS/ICONS Key/Icon... HalfloadsolenoidvalveOFF HalfloadsolenoidvalveON Defrost OFF Defrost ON (Full load) (Halfload) 144V739E4.00 · Vcolor 739 M/L | 30 | 12/2022...
  • Page 31: Using The Controller

    Switching on 28/01/2021 07:31 21.3 °C 28/01/2021 07:31 FAVORITES SPECIALS PROGRAMS MACHINE NAME Switching off 28/01/2021 07:31 21.3 °C 28/01/2021 07:31 SPECIALS FAVORITES PROGRAMS MACHINE NAME Fig. 17. Controller ON/OFF NOTE:byswitchingON/OFFwemeanswitchingfromSTANDBYtoONandvice-versa. 144V739E4.00 · Vcolor 739 M/L | 31 | 12/2022...
  • Page 32: Backlighting

    28/01/2021 07:31 From here you can: • Switchoffthedevice; • Accessthelistoffavouritecycles; • Accessthesettingsmenu; • Accesstherecipebook; FAVORITES SPECIALS PROGRAMS • Accessspecialcycles; • Login to EXPERT or OEM levels. MACHINE NAME Fig. 19. Home screen 144V739E4.00 · Vcolor 739 M/L | 32 | 12/2022...
  • Page 33: Settings Menu

    28/01/2021 07:31 IMPOSTAZIONI DATA LOG ALARM LIST DATE/TIME FAVORITES SPECIALS PROGRAMS MACHINE INFO LANGUAGE IN/OUT STATUS MACHINE NAME SETTINGS OUTPUT TEST INTERNAL DATA RESET PARAMETERS Fig. 21. Settings menu, EXPERT level 144V739E4.00 · Vcolor 739 M/L | 33 | 12/2022...
  • Page 34 Machine info √ √ √ Change language √ √ √ I/O status √ √ √ Output test √ √ Internal data reset √ √ View/change parameters √ √ PID setup √ 144V739E4.00 · Vcolor 739 M/L | 34 | 12/2022...
  • Page 35: Data Log

    • Date and time at which the recipe was carried out. 5.7.3 Counter log The following information is shown on this screen: • Total machine running time; • Compressor running time; • Heaterrunningtime; • Anycondensercleaningalerts. 144V739E4.00 · Vcolor 739 M/L | 35 | 12/2022...
  • Page 36: View Alarm List

    Fig. 25. Change Date and Time NOTE: only the EU date/time format can be used. 5.10 MACHINE INFO The Machine info screen shows information relating to: • Machinefirmware; • Machine name; • Manufacturer data. 144V739E4.00 · Vcolor 739 M/L | 36 | 12/2022...
  • Page 37: Change Language

    GEARMOTOR INPUT INACTIVE SOLENOID VALVE INACTIVE THERMAL COMPR. INPUT INACTIVE CONDENSER FANS INACTIVE HIGH PRESS. COMPR. INPUT ACTIVE CRANKCASE HEATER ACTIVE THERMAL HEATERS INPUT ACTIVE HALF-LOAD VALVE INACTIVE Fig. 27. IN/OUT status 144V739E4.00 · Vcolor 739 M/L | 37 | 12/2022...
  • Page 38: Output Test (Expert/Oem Only)

    The Internal data reset function can be used to: • Restore the parameters to the factory-set default values; • Delete the data log; • Delete machine operating time counter data; • Delete the alarm log; • Delete OEM recipes. 144V739E4.00 · Vcolor 739 M/L | 38 | 12/2022...
  • Page 39: Parameter Management (Expert/Oem Only)

    INTEGRAL TIME (r15) 100sec DERIVATIVE TIME (r16) 0sec CYCLE TIME (r17) 5sec PARAMETERS Fig. 31. PID setup This function can be used to change the parameters used for PID regulation on heater startup. 144V739E4.00 · Vcolor 739 M/L | 39 | 12/2022...
  • Page 40: Recipe Book

    Filling in the recipe info screen Assigning a product name and photo to the recipe Changing recipe values before the cycle starts or while it is in progress Saving recipe changes 144V739E4.00 · Vcolor 739 M/L | 40 | 12/2022...
  • Page 41: Introduction

    HALF LOAD ENABLE ENABLE EDIT ENABLE MODE 1 CONS MIXER MODE HEATING MODE 1350 PAUSE 0 CLOCKWISE COOLING MODE CLOCKWISE Fig. 33. Creating recipes from an .ods file - phases Thetemperaturevaluesshouldbeenteredintenthsofadegree(example:toset-20.0°C,enter-200;toset4°C,enter40). Thetimevaluesshouldbeexpressedinseconds(example:toset1minute,enter60;toset5minutes,enter300). 144V739E4.00 · Vcolor 739 M/L | 41 | 12/2022...
  • Page 42: Cooking Phases

    • Maximum OFF time that can be set for the mixer arm. NOTE: a maintenance phase can be set with cooling regulation (instead of neutral zone) by setting the density setpoint for the recipe to value 101. 144V739E4.00 · Vcolor 739 M/L | 42 | 12/2022...
  • Page 43: Creating A Recipe With Mixture Density Control Via .Ods File

    The maximum size of the ingredients list is 10 lines of 28 characters each. Description/Preparation The maximum size of the description string is 13 lines of 20 characters each. NOTE:donotusethe"Comma” character (,). 144V739E4.00 · Vcolor 739 M/L | 43 | 12/2022...
  • Page 44: Assigning A Product Name And Photo To The Recipe

    Changingtherecipevaluesonlyaffectsthecycleinprogress.Oncethecycleiscomplete,thechangesmadearerestoredtothe factoryvalues.Ifthevalueenteredisoutsidethepermittedrange(shownonthedisplay),thefollowingmessageappears: MIXER SPEED MIXER SPEED 07:31 - 25/11/2019 MIXER SPEED NEW VALUE VALUE IS NOT WITHIN THE LIMITS MIN 40 / MAX 240 Fig. 38. Value outside the range entered 144V739E4.00 · Vcolor 739 M/L | 44 | 12/2022...
  • Page 45: Advanced Configurations

    PAUSE SPEED MIXER SPEED 120RPM PAUSE TIME MIXER ON TIME 20sec MIXER OFF TIME 10sec MIXER ON TIME 20sec MIXER OFF TIME 10sec ADVANCED CONFIGURATIONS Fig. 39. Recipe program advanced configurations 144V739E4.00 · Vcolor 739 M/L | 45 | 12/2022...
  • Page 46: Saving Recipe Changes

    60RPM NEW VALUE PAUSE STORAGE PAUSE SPEED MIXER SPEED 120RPM PAUSE TIME MIXER ON TIME 20sec MIN 40 / MAX 240 MIXER OFF TIME 10sec Fig. 41. Editing in real time 144V739E4.00 · Vcolor 739 M/L | 46 | 12/2022...
  • Page 47: Key Functions

    Tapping inside the area on the left shows the 6 data samples on the left-hand side; tapping inside the area on the right shows the second group of six data samples. Thegraphisbasedonsamplesthataretakenwhileacycleisbeingcarriedout,thereforethegraphcanonlybecreatedifat least two samples are available. 144V739E4.00 · Vcolor 739 M/L | 47 | 12/2022...
  • Page 48 The sampling time is governed by parameter rE0. Thecoloursofthegraph,backgrounds,lines,etc.,aredefaultsettingsandcannotbechanged. Toreturntothepreviousscreen,waitforafewseconds. Legend of colours Colour Description Black Background Darkgrey Grid Light grey Setpoint Orange Tankprobetemperature Heaterprobetemperature Blue Condenser probe temperature Yellow Density 144V739E4.00 · Vcolor 739 M/L | 48 | 12/2022...
  • Page 49: Functions

    Chapter content This chapter contains the following information: Subject Page Standard operation Operation with special maintenance Operation with mixture density control Special cycles Independent safety temperature for each recipe Power failure management 144V739E4.00 · Vcolor 739 M/L | 49 | 12/2022...
  • Page 50: Standard Operation

    OFF time period (t04),atspeedt06. When the compressorisreactivated,thearmresumesitsrotationcontinuouslyfortheentireactivationtime.Thephaseendswhenthe program start date and time selected at the Start is reached. The program can always be ended at any time by pressing Ifspecified,theamountofproductinthemachinecanbeselectedbytappingFullload/Halfload.Duringtheconservationdueto delayedstartphase,theHACCPdataisstoredintheHACCPlogandcanbedownloadedviatheUSBportonthebackoftheuser interface. 144V739E4.00 · Vcolor 739 M/L | 50 | 12/2022...
  • Page 51: Cooking, Pause And Cooling Phase

    • Temperature regulation ends; •  T hearmworkscontinuouslyatthemaintenancespeed(thisfacilitatesextractionoftheproductfromthespecificdoor). Ifthetemperatureofthetankis<d2,adefrostcyclebeginsautomaticallyinordertoheatthetankwallsandmakeproduct extraction easier. Duringtheextractionphase,youcan: • Change the speed of the arm; • Startamanualdefrostcycle; • Startacleaningcycle; • Permanently end the cycle (by tapping 144V739E4.00 · Vcolor 739 M/L | 51 | 12/2022...
  • Page 52: Operation With Special Maintenance

    Density = (E10 x AbsorbedCurrent + E11 x AbsorbedCurrent + E12) The values to enter for the 3 coefficients vary depending on the power cut of the connected EVCO inverter and based on the size ofthemachinetank. 144V739E4.00 · Vcolor 739 M/L...
  • Page 53: Special Cycles

    7.4 SPECIAL CYCLES Vcolor 739 offers 3 special cycles: • Cooling cycle; • Cleaning cycle; • Continuous mixing cycle (only with EVCO inverter connected). 7.4.1 Cooling cycle Oncethecoolingcyclehasbeenselected,Vcolor 739willaskyoutoselectthecoolingsetpoint(defaultt13 shown). to launch the cycle with the selected setpoint. Whileitisrunning,thefollowingcanbechanged: • The temperature setpoint;...
  • Page 54: Regulators

    Chapter content This chapter contains the following information: Subject Page Heaters Compressor Condenser fans Crankcase heater Half/full load solenoid valve Technical room fans Defrost solenoid valve Gearmotor Single speed arm rotation 144V739E4.00 · Vcolor 739 M/L | 54 | 12/2022...
  • Page 55: Heaters

    8.7 DEFROST SOLENOID VALVE Thiscanonlybeactivatedifenabledfortherecipeinprogress,duringthecoolingphase. Thefirstkeytapactivatestheoutput,theseconddeactivatesit.Ifitisnotdeactivatedviakey,whenthetimegivenind3elapses, it is nevertheless deactivated. Ifthecoverisopened,itisstillactivatedforthetimeperiodd3 or until the cover is closed. During defrost solenoid valve activation the compressor and the cooling solenoid valve are switched on. Attheendofthesolenoidvalveactivationtime,thecompressorandthecoolingsolenoidvalvereverttonormalregulation. Atthestartofanextractionphase,ifthetemperatureofthetankislowerthand2,adefrostbeginsautomatically. 144V739E4.00 · Vcolor 739 M/L | 55 | 12/2022...
  • Page 56: Gearmotor

    8.9 SINGLE SPEED ARM ROTATION This output is used when the machine is in single speed configuration without using the Inverter. It is activated when the mixer needs to be activated. 144V739E4.00 · Vcolor 739 M/L | 56 | 12/2022...
  • Page 57: Parameters

    9. PARAMETERS Chapter content This chapter contains the following information: Subject Page Description of columns in the Table of Parameters Table of configuration parameters for Vcolor 739 Table of Inverter configuration parameters 144V739E4.00 · Vcolor 739 M/L | 57 | 12/2022...
  • Page 58: Description Of Columns In The Table Of Parameters

    °C/°F 1.0...50.0 20.0 r14 Proportionalbandfortankproberegulationmanagement. °C/°F 1.0...50.0 10.0 r15 Integral action time. 0...999 r16 Derivative action time. 0...250 r17 Cycle time for PID regulation. 5...60s r18 RESERVED. P35 Density hysteresis 1...40 144V739E4.00 · Vcolor 739 M/L | 58 | 12/2022...
  • Page 59 2...99=AddressforEPOCAlocalnetwork. rE0 Internal data sampling time. 1...60 Modbus protocol controller address. 0...247 Modbus transmission speed (baud rate). 0 = 2400; 1 = 4800; baud 0...3 2 = 9600; 3 = 19200. 144V739E4.00 · Vcolor 739 M/L | 59 | 12/2022...
  • Page 60 Enable mixer direction control 0 = Disabled; 1 = Enabled. E14 Maintenance interval. 200...800 Only applies if P68≠0 Only applies if P68≠0andE13 = 1. NOTE: changing the parameters causes the controller to restart. 144V739E4.00 · Vcolor 739 M/L | 60 | 12/2022...
  • Page 61: Table Of Inverter Configuration Parameters

    The minimum and maximum limits are calculated on the basis of the number of pole pairs for the motor, i.e. between 5 and 100 Hz; Looking at the motor with the shaft positioned to the front; Parameter depends on the motor rating label; In alarm or emergency conditions, stoppage is always the free type. 144V739E4.00 · Vcolor 739 M/L | 61 | 12/2022...
  • Page 62: Diagnostics

    10. DIAGNOSTICS Chapter content This chapter contains the following information: Subject Page Introduction Table of Vcolor 739 alarms Table of inverter alarms 144V739E4.00 · Vcolor 739 M/L | 62 | 12/2022...
  • Page 63: Introduction

    • Alarmshownondisplay Checkforandremovethecause Compressor high pressure compressor • Recording in alarm log of the alarm on the digital input digital input open (i21) alarm • Cycle inhibited if in cooling (automatic reset) 144V739E4.00 · Vcolor 739 M/L | 63 | 12/2022...
  • Page 64: Table Of Inverter Alarms

    Inverter • Restore communication between No communication between • Recording in alarm log communication base board and inverter base board and inverter • MODBUScommunicationinterrupted alarm • Automaticreset • Load regulation inhibited 144V739E4.00 · Vcolor 739 M/L | 64 | 12/2022...
  • Page 65 This page has been left blank on purpose. 144V739E4.00 · Vcolor 739 M/L | 65 | 12/2022...
  • Page 66 Each user or integration specialist should conduct their own complete and appropriate risk analysis, in addition to carrying out a product evaluation andtestinrelationtoitsspecificapplicationoruse. Neither EVCO nor any of its associates or subsidiaries shall be held responsible or liable for improper use of the information contained herein. MADE IN ITALY EVCO S.p.A.

This manual is also suitable for:

Vcolor 739 l

Table of Contents