Evco Vcolor 368 M Installer Manual
Evco Vcolor 368 M Installer Manual

Evco Vcolor 368 M Installer Manual

Controllers for combination ovens for gastronomy and pastry making
Hide thumbs Also See for Vcolor 368 M:
Table of Contents

Advertisement

Quick Links

EVCO S.p.A.
Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104
Vcolor 368 M & L
Controllers for combination ovens
for gastronomy and pastry making
ENGLISH
INSTALLER MANUAL ver. 1.0
CODE 144VC368E104
page
of
1
62

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Vcolor 368 M and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Evco Vcolor 368 M

  • Page 1 EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 Vcolor 368 M & L Controllers for combination ovens for gastronomy and pastry making ENGLISH INSTALLER MANUAL ver. 1.0 CODE 144VC368E104 page...
  • Page 2 EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 Important Read this document carefully before installation and before using the device and take all the prescribed precautions. Keep this document with the device for future consultation.
  • Page 3: Table Of Contents

    EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 Index INTRODUCTION ............ 4 10.3.3 Boiler rinsing ............31 Product description ..........4 10.3.4 Boiler washing ............ 32 Models available and hardware features ....5 BURNER EXPANSION ...........
  • Page 4: Introduction

    Product description Vcolor 368 M & L controllers manage all the most up-to-date functions of electric combination ovens for gastronomy and pastry- making. Additional optional modules also make it possible to control ovens with an external boiler and gas burners.
  • Page 5: Models Available And Hardware Features

    EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 Models available and hardware features The table below shows the technical features of the models available and the purchasing codes. EVCMC36DJ2E EVCMC36DC2E EVCLC36DJ2E EVCLC36DC2E Power supply 1.2.1...
  • Page 6 EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 Suction hood Configurable (default washing water valve) Configurable (default washing liquid detergent injection) (2) Configurable (default washing liquid discharge) (2) Configurable (default rinse aid injection) (2) Communications ports 1.2.11...
  • Page 7 EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 The table below shows the purchasing codes. Vcolor 368M (control module + 5-inch user interface kit) EVCMC36DJ2E for J/K thermocouples EVCMC36DC2E Pt 100 2 wires...
  • Page 8: Installation

    EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 INSTALLATION Format features The control module is available in a split version with an open frame board. User interfaces are available in 5 or 7-inch versions for vertical operation and have capacitive colour TFT touch-screen graphic displays.
  • Page 9 EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 7-inch user interface The user interface is panel mounted from the front Installation precautions - ensure that the working conditions for the device (operating temperature, humidity, etc.) are within the set limits. See section 17 TECHNICAL SPECIFICATIONS.
  • Page 10: Vcolor 368M Electrical Connection

    EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 Vcolor 368M electrical connection The picture below shows the electrical connection of devices with a 5-inch user interface. For more information on how to manage ventilation see subsequent pictures.
  • Page 11 EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 page...
  • Page 12: Vcolor 368L Electrical Connection

    EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 Vcolor 368L electrical connection The picture below shows the electrical connection of the device with a 7-inch user interface. For more information on how to manage ventilation see subsequent pictures.
  • Page 13 EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 page...
  • Page 14 EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 Fan management in “on/off” and single speed mode (parameter F0 = 0) Fan management in "on/off" and single speed mode and with inversion of the fan direction (parameter F0 = 1)
  • Page 15 EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 Fan management in "on/off" and two-speed mode and with inversion of the fan direction (parameter F0 = 2) Fan management in modulating mode and with inversion of the fan direction (parameter F0 = 3) The RS-485 MODBUS communications port enables connection to the Parameters Manager set-up software.
  • Page 16 EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 Example of connection of a motorised venting solenoid valve. The following diagram and the following timings are an example of the way the "FIBER" venting mechanism type can be operated.
  • Page 17: Operating The Device

    EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 OPERATING THE DEVICE Switching the device on/off After having connected the power to the device, wait for the system to load. On the Stand-by page, touch the icon in the centre to access the Home page.
  • Page 18: Manual Cooking

    EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 Below is an overview of the pages and the icons used and their description. For more information on the functions, see the sections below. Manual cooking...
  • Page 19: Settings And Status

    EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 A la carte menu Regeneration Resting Cooling Washing Settings and status The settings and status menu can be accessed from the home page by touching the icon at the top right.
  • Page 20: Internal Status

    EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 4.5.2 Internal status The screen displays just the main status of the unit. To display all the internal status data, the password +19 must be entered on the SERVICE screen.
  • Page 21: Planning

    EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 Planning The weekly programmed switch-on can be accessed from the home page by touching the icon at the top left. page...
  • Page 22: Cooking Function

    EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 COOKING FUNCTION Initial information Cooking can be by convection, steam or mixed. Each cooking cycle consists of a minimum of one up to a maximum of six phases. At the end of each phase the device automatically moves on to the next one.
  • Page 23: Method Of Operation For Ventilated Bread And Pastry

    EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 Method of operation for ventilated bread and pastry-making ovens By configuring the parameters appropriately, the controller set-up can be adapted to enable management of ventilated bread and pastry-making ovens.
  • Page 24: Starting/Interrupting The Cooking Cycle

    EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 - From any of the phases making up the cycle, press “End recipe” Selecting pre-heating, type of cooking and method of phase control. Setting the working setpoint.
  • Page 25 EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 On completion of the cooking cycle, the buzzer is activated for the length of time set by parameter c0. To interrupt the cooking cycle manually, press STOP for one second.
  • Page 26: "Recipe Book" Function

    This function is primarily for the benefit of OEM/DISTRIBUTORS who can load their recipe books themselves for use by their own clients. For details of the procedure illustrating how to set up the OEM recipe book, please contact the EVCO sales network. My recipes This recipe book is for the use of end users who will be able to save the settings of personalised cooking cycles in a recipe.
  • Page 27: Starting Up A Recipe

    EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 Starting up a recipe To start up a recipe, proceed as follows: - Ensure that the device is switched on and that no procedure is in progress.
  • Page 28: Special Cycles Function

    EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 SPECIAL CYCLES FUNCTION Initial information The “Special cycles” function lets you take advantage of ready-to-use work cycles. You can start one of the following work cycles:...
  • Page 29: À La Carte" Cooking Cycle

    EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 “À LA CARTE" cooking cycle The "à la carte" cooking cycles allow the oven to cook simultaneously trays with different dishes and with different cooking times but of the same cooking types (for the temperature and humidity settings).
  • Page 30: "Weekly Programmed Switch-On" Function

    EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 “WEEKLY PROGRAMMED SWITCH-ON" FUNCTION Initial information The “Weekly Programmed Switch-on” function makes it possible to programme the device to start up a maximum of 9 times a week and at the same time to start up a recipe.
  • Page 31: Boiler Expansion

    EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 10 BOILER EXPANSION 10.1 Activating expansion The following conditions must be met to enable EVCLE305XXE boiler expansion: Enable the boiler by setting parameter T15 (T15 = 1) Set the steam generation mode with external or mixed humidification by setting parameter T0 (T0 = 1 or 2) The boiler temperature probe can be enabled/disabled by parameter, without affecting boiler operation.
  • Page 32: Boiler Washing

    EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 Should the emptying not take place, the “BOILER EMPTYING” alarm will be activated. The alarm can be reset with the key. If the maximum level is not reached within the prescribed time (parameter t28), the “MAX. BOILER WATER LEVEL” alarm signal will be activated.
  • Page 33: Burner Expansion

    EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 11 BURNER EXPANSION 11.1 Activating expansion To enable burner expansion, parameter b14 must be set to: 1 where a modulated air blown burner is being used 2 where an on-off atmospheric burner is being used 11.2 Managing a modulated air blown burner...
  • Page 34: On-Off Atmospheric Burner Management

    EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 11.3 On-off atmospheric burner management When the oven receives a request to heat, the output (chamber or boiler) is activated by a command to the control unit that automatically manages the burner.
  • Page 35: Application Diagram

    EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 11.5 Application diagram The EVCLE302XXE burner module interacts with electronic ignition circuit boards for Honeywell series 4565 and similar atmospheric burners and with variable speed centrifugal fans with PWM control + feedback.
  • Page 36: Managing The Loads

    EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 12 MANAGING THE LOADS 12.1 Temperature regulation Depending on the value of parameter r13, temperature regulation can be ON-OFF or PI (Proportional-Integral). NB: PI regulation is available only for electric ovens.
  • Page 37: Managing Outputs For Special Washing Cycles

    EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 To set the configuration parameters, see section 13. 12.8 Managing outputs for special washing cycles The controller has 4 relay outputs designed to manage two different types of wash:...
  • Page 38: Washing With Tablet Detergent, With Recirculation Of

    EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 Phase 3 - Rinse aid: Once the washing is completed, the “rinse aid” phase begins. The K13 relay, “liquid rinse aid dispensing pump” is activated for w9 seconds. If w20 = 1, the injection output and the water solenoid valve relay will both be activated.
  • Page 39 EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 - Rinsen - SOFT wash - MEDIUM wash - HARD wash The "Rinsen" wash type is a cycle with a special sequence; the other types of cycle differ in the number of repetitions of the washing phase carried out.
  • Page 40 EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 Phase 2B - Washing Preparation The oven is adjusted to the “Washing Preparation “ temperature (parameter w8) with humidification at 100% for w11 minutes, during which the K10 relay (solenoid valve supplying mains water to the condenser) is also activated.
  • Page 41: List Of Configuration Parameters

    EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 13 LIST OF CONFIGURATION PARAMETERS The table below describes the configuration parameters of the device. PARAM. MIN. MAX. U.M. DEF. ANALOGUE INPUTS Type of probe...
  • Page 42 EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 Working setpoint during pre-heating (referring to the working setpoint during the first cooking cycle phase, i.e. “working setpoint during the °C/°F -199 first cooking cycle phase + r10”; referring to the temperature detected by the chamber probe).
  • Page 43 EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 2 = in "on/off" and two-speed mode and with inversion of the fan direction 3 = in modulating mode and with inversion of the fan direction Time the fan is switched off for the purpose of direction inversion (only if F0 = 1, 2 or 3).
  • Page 44 EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 (for Mixed cooking type) Duration of injection of steam generated by an external humidifier to obtain maximum humidification (for Mixed cooking type) Delay of injection of steam generated by an external humidifier from...
  • Page 45 EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 Humidification value display - - - 0 = percentage (gastronomy ovens) 1 = in seconds (bread/pastry ovens) Enable constraint between injection of generated steam and the vent - - - = YES –...
  • Page 46 EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 Fan thermal switch input type - - - normally open (input active with contact closed) normally closed (input active with contact open) - - -...
  • Page 47 EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 PARAM. MIN. MAX. U.M. DEF. WASHING °C/°F Working setpoint for prewash phase °C/°F Prewash activation enable differential Prewash time °C/°F Working setpoint for washing phase...
  • Page 48 EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 1000 3000 1000 Chamber burner ignition RPM °C/°F Band for chamber temperature proportional regulation Chamber ramp time 1000 Chamber burner alarm RPM Chamber burner RPM alarm delay...
  • Page 49 EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 °C/°F Chamber temperature cooling warning band while cooking Preset colour schemes 0= dark background, light text 1= light background, dark text 2= light background, red text...
  • Page 50: Using The Usb Port

    EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 14 USING THE USB PORT 14.1 Initial information The USB port makes possible the following operations. - Upload and download of the settings in the recipes of the “My Recipes” function and in the working cycles of the “Special Cycles”...
  • Page 51: Download Of Haccp Data Stored Within The Controller51

    EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 14.6 Download of HACCP data stored within the controller If a USB flash drive is connected, in addition to the upload/download parameters and recipes, the item DOWNLOAD HACCP DATA also appears.
  • Page 52: Alarms

    EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 15 ALARMS 15.1 Alarms If an alarm happens the buzzer sounds and the display shows the icon and a pop-up message with an alarm code. Touch the display near the centre to silence the buzzer and restore the normal view.
  • Page 53 EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 User interface-control module communication alarm To correct Control module - Check the user interface-control module connection communicat. Main results ALARM - If the alarm is raised when the device is on, it will not be possible to start up a cooking cycle...
  • Page 54 EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 The boiler water does not reach the minimum level To correct Low water level - Check the boiler input; see parameter t27 ALARM Main results...
  • Page 55 EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 Safety thermostat input alarm To correct Thermal switch Check the cause of the input activation; see parameter i3 ALARM Main results if the alarm occurs during a cooking cycle, the cycle will be interrupted...
  • Page 56: Accessories

    EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 16 ACCESSORIES 16.1 Non-optoisolated RS-485/USB serial interface The interface enables the device to be connected to the Parameters Manager set-up software system. 16.2 USB plug for panel installation The plug makes the USB communications port of the device more accessible.
  • Page 57: Technical Specifications

    EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 17 TECHNICAL SPECIFICATIONS 17.1 Technical specifications Purpose of the control device function controller Construction of the control device built-in electronic device user interface control module Container black, self-extinguishing.
  • Page 58 EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 12 VAC (±15%), 50/60 Hz (±3 Hz), provided by the control module 20 VA max. Rated impulse-withstand voltage 4 KV Over-voltage category III. Software class and structure Built-in Autonomy in the absence of a power supply: 24 hours with full charge.
  • Page 59 EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 digital inputs for high voltage contact Power supply: 230 VAC. Protection: none. 1 0-10 V output for fan management (in this case an external speed regulator Analogue outputs should also be used).
  • Page 60 EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 page...
  • Page 61 EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 Vcolor 368 Controller for combination ovens for gastronomy and pastry making Installer manual ver. 1.0 GA - 37/18 Code 144VC368E104 This document and the solutions contained therein are the intellectual property of EVCO and thus protected by the Italian Intellectual Property Rights Code (CPI).
  • Page 62 EVCO S.p.A. Vcolor 368 M & L | Installer manual ver. 1.0 | Code 144VC368E104 EVCO S.p.A. Via Feltre 81, 32036 Sedico Belluno ITALY Tel. 0437/8422 | Fax 0437/83648 info@evco.it | www.evco.it page...

This manual is also suitable for:

Vcolor 368 l

Table of Contents