Advertisement

SOYAL
ACCESS & INDUSTRIAL CONTROL
Content
1
Product
2
Terminal Cables
CN1
AR-101-H/U
Feature
AR-101-H
Selectable working frequencies: 13.56MHz
Including the input of door contact, offering the alarm system of both
door opening too long and being forced to open
Built-in Multi-Output: Door Lock/ Alarm/ Security trigger signal
Have the "MASTER CARD" functions, convenient operation
Mini Flush-Mounted design gives neat installation
Elegant design with colorful Edge Indicator
Connector Table
CN1
AR-101-H
8PIN Cable
Function
Wire
1
2
Lock Relay
3
Door Contact
4
Exit Switch
5
Alarm
6
7
Power
8
AR-101-H/U
CN2
2PIN Cable
Function
Wire
1
RS-485
2
AR-101-H/U
J3
4PIN Cable
Function
Wire
1
2
Wiegand Reader/
Ex. Keyboard
3
4
AR-101-U Dip-switch &
Wire
Dip-switch-SW1
---
Dip-switch-SW2
---
Description
---
1
2
3
4
CN1 Cable
5
6
7
8
®
3
Black ABS
4
CN2
Color
Description
Blue White (N.O.) DC24V1Amp
Purple White (N.C.) DC24V1Amp
White
(COM) DC24V1Amp
Orange
Negative Trigger Input
Purple
Negative Trigger Input
Transistor Output Max. 12V/100mA
Gray
(Open Collector Active Low)
Thick Red
DC 9~24V
Thick Black DC 0V
Color
Description
Thick Green RS-485(B-)
Thick Blue
RS-485(A+)
Color
Description
Thick Red
DC 9~24V
Thick Black DC 0V
Thick Blue
Wiegand DAT:1 Input
Thick Green
Wiegand DAT:0 Input
CN1
8PIN Cable
Color
RS-485 Mode/
Polling Mode
(Connected to AR-716-E16)
---
ON
---
ON
Auto-open Time Zone
Auto Open with
---
swiping 1st valid
card at Auto-open
Time Zone
Blue White
---
Green White ---
White
Door Lock Output
Orange
Door Sensor
Purple
Exit Button
Gray
Buzzer
Thick Red
Power
Thick Black
AR-101-H/U
Optional (panel)
5
Optional(only 101-H)
Wiegand Keyboard :
AR-WG-KEYBOARD
DMET-101PJ
AR-101-U (RS485/WG)
Selectable working frequencies: 125KHz/13.56MHz
From the DIP switch to select to be RS485 or WG output reader
Flexible to integrate with SOYAL or other access control system
Interface of the Proximity Reader have WG26/34 (By order)
Elegant design with colorful Edge Indicator
Flush-Mounted Design gives neat installation
※ Dip-switch is only available for AR-101-U
*Dip-switch must adjust at 2nd layer of mainboard.
Highly suggest to fixed WG34/26 before order
How to adjust dip-switch:
A
Step 1.
Open lightly the upper board
cover with screwdriver
Function
WG Mode
OFF
ON
ON
OFF
WG34
(default)
Auto-open door at
auto open zone
WG Output
---
LED R
LED G
- 1 -
Extenal Relay :
or
AR-821-RB
AR-721-RB
ON
1
2
Front
B
B
ON
1
Step 2.
Adjust the DIP switch according to
the function and put upper cover
back on the upper board
OFF
OFF
Description
WG26
WG DATA 1 Output
WG DATA 0 Output
Transistor Output Max. 24V/1.5A
(Open Collector Active Low)
Negative Trigger Input
Negative Trigger Input
Transistor Output Max. 12V/100mA
(Open Collector Active Low)
DC 12V
DC 0V
V221024
Master Card :
(Keyless editing)
1
CN2
2
1
2
3
4
4
5
CN1
3
6
J3
2
7
1
8
Back
A
2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AR-101-H and is the answer not in the manual?

Questions and answers

Summary of Contents for Soyal AR-101-H

  • Page 1 From the DIP switch to select to be RS485 or WG output reader door opening too long and being forced to open Flexible to integrate with SOYAL or other access control system Built-in Multi-Output: Door Lock/ Alarm/ Security trigger signal Interface of the Proximity Reader have WG26/34 (By order) Have the "MASTER CARD"...
  • Page 2: Access Controller

    Use a screwdriver to screw the mounting plate on the wall. Paste the label sticker to finish installation. Diagram Optional WG Reader/ Ex. Keyboard AR-101-U AR-WG-KEYBOARD Power 9~24VDC AR-101-H USB Converter TCP/IP Converter Electric Bolt(AR-1207) Magnetic Lock Cabinet Lock Electric Strike Alarm EXIT Wiring...
  • Page 3: Operation Process

    V221024 ACCESS & INDUSTRIAL CONTROL About Master Card ( Below programming is for AR-101-H only ) MASTER CARD Setting for keyless editing Plug in cable , the wire connection is as below figure. After connection, then have power transmission to controller.
  • Page 4: Arming Mode

    Access Controller V221024 B. Set up the password [Only for connect to external K-series reader] M4/M8: Individual pass code Card or PIN: Access programming mode → 12 UUUUU ???? [e.g. User address: 00001 and pass code: 1234, input 12 00001 1234 Card and PIN: Access programming mode →...
  • Page 5: Factory Reset

    ※ [The normal procedure to open door] can refer to [Access Mode]. More Details: ※ Read the [Command List-Arming /Duress Function Setting] below to modify arming PWD. SOYAL Security Related Function ※ M6 is Standalone Mode, the mode is without Arming /Duress Function. Compound Command Function List...
  • Page 6: Command List

    Access Controller V221024 Command List Function Description Command Master PPPPPP=Master Code, default value=123456 Enter program mode PPPPPP Code PPPPPP=6-digit new master code PPPPPPRRRRRR Master code setting Setting RRRRRR=Reconfirm the new master code Suspend tag SSSSS EEEEE =Suspend =Delete; SSSSS EEEEE Delete tag SSSSS=Starting User Address;EEEEE=Ending User Address SSSSS=Starting card number...
  • Page 7 SOYAL ® AR-101-H/U V221024 ACCESS & INDUSTRIAL CONTROL Function Command Description Reader additional setting Please refer to Compound Command Function List Controller parameter setting for details. Double Door Control / Force Open Alarm N= 0 (1st time zone) / 1 (2nd time zone) HHMM= Starting time;...

This manual is also suitable for:

Ar-101-u