Soyal AR-725-E Manual
Hide thumbs Also See for AR-725-E:

Advertisement

Quick Links

SOYAL
ACCESS CONTROL SYSTEM
Contents
AR-725-E-M
1
Products
A.
B.
AR-725-E
1
Products
A1.
E.
AR-725 (X)
1
Products
A2.
A3.
Parts Description
Button Head Pozidriv
a.
Tapping Screw: M3x10
d.
Security Torx Screw:
M3.5x15
Installation
AR-725-E-M
3
A.
A.
2
C.
4
1
B.
c.
AR-725-E
F.
1
AR-725 (X)
A1.
A3.
1
b.
G.
®
C.
D.
F.
B.
C.
G.
b.
e.
A.
B.
C.
B.
6
5
F.
E.
A1.
3
4
e.
f.
5
A1.+A3.
H.
A2.
e.
f.
AR-725-E
2
Terminal Cables
CN4
CN6
CN3
CN11
Optional wafer cables for additional purchase for TTL
integration with peripheral devices or floor control.
2
Terminal Cables
CN4
CN6
CN3
CN11
Optional wafer cables for additional purchase for TTL
integration with peripheral devices or floor control.
H.
D.
Button Head Pozidriv
Slotting Screw: 2.5x10
Flat Head Hex Socket
Screw: M3x8
Pull the cables from the square access hole of the mounting plate C.
Use a screwdriver to screw the metal plate C to the wall.
A.
7
Take off the plastic mounting plate B from the body A, and pull the cables
C.
through the access hole of C and B, then connect to the body A.
Assemble plate B with the body A, and embed the water proof strip D
onto the plastic side frame.
d.
8
Assemble the body A onto the mounting plate C with the Allen key and
D.
g.
screws (accessories supplied).
Turn on the power and LED will light and beep will sound.
Use a screwdriver to screw the base F onto the wall.
Attach the water proof gasket to the body A1, and pull the cables
2
from the square hole of the base F, and connect to the body A1.
Assemble the body A1 with the base F.
Screw A1 and F tight with the Allen key and screws (accessories
supplied).
Turn on the power and LED will light and beep will sound.
Put on G, and attach A1 onto the plastic plate A3, and screw it with
the Allen key and screws (accessories supplied).
D.
Put the ring O on the metal frame, and put them together onto the
reader A1+A3, and screw them and buckle up the 4 buckles on the
4
back.
a.
Embed the water proof strip D onto the frame side of the base.
5
Following by the install process of AR-725-E-M.
CN5
CN7
CN8
CN11
CN5
CN7
CN8
CN11
2
Tools
a x2
b x2
c x2
Flat Head Cap Philips
c.
Tapping Screw: 4x19.1
f.
V220221
3
Tools
c x2
d x1
f x1
3
Tools
e x1
d x1
f x1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AR-725-E and is the answer not in the manual?

Questions and answers

Summary of Contents for Soyal AR-725-E

  • Page 1 Put the ring O on the metal frame, and put them together onto the reader A1+A3, and screw them and buckle up the 4 buckles on the back. Embed the water proof strip D onto the frame side of the base. Following by the install process of AR-725-E-M.
  • Page 2: Access Controller

    Access controller Illuminated Touch-panel V220221 Notice 1. Tubing: The communication wires and power line should NOT be bound in the same conduit or tubing. 2. Cable selection: Use AWG 22-24 Shielded Twist Pair to avoid star wiring. Use CAT5 for TCP/IP connection. 3.
  • Page 3 ※ The Wiring of Disable "Share Door Relay" ( Set up via the parameters setting Window of 701ServerSQL) setting Window of 701ServerSQL AR-725-E become WG mode (28 725 (E-V2) WGoutput 725 (E-V2) Master 1. When AR-725-E become WG mode,it can be used with any controllers. Duress RLED ※Using Rule : GLED...
  • Page 4 (NN=00~15); HHMMhhmm=Starting time to ending time; 7123456H= 7 days of week + Holiday (F= 0: disable; 1: enable)] [e.g.]AR-725-E (without WG reader), to set second time zone which could be passed only at 9:30am to 4:20pm on Mon, Wed and Fri.
  • Page 5: Restoring Factory Settings

    Firmware Upgrade Get the upgrade software from SOYAL or our distributor and run “UdpUpdater” software Execute the software The software is within SOYAL CD or Login the...
  • Page 6: Command List

    Illuminated Touch-panel V220221 IP Setting IP Setting Open your Web Browser and input factory default IP address: http://192.168.1.127 If the IP address of AR-725-E has changed We must enter the new IP address. Page menu Page menu Monitor the on-line computer...
  • Page 7 AR-725-E V220221 ACCESS CONTROL SYSTEM Command List Function Command Exposition U=Enable target unit (0=AR-725-E , 1=WG Reader) Door relay time setting TTT=Door relay time;000 (Output constantly) 001~600=1-600 Sec.;601~609=0.1~0.9Sec. TTT=Alarm relay time;000 (Output constantly) Alarm relay time setting 001~600=1~600 Sec. Mode setting M=4 (Mode 4);M=8 (Mode 8)
  • Page 8: Function Default Value

    MM= Month of year (01=Jan...10=Oct.) Holiday Setting MMDD DD= Date of month (01=1st day of month) F= 0:Delete ; 1: Add M=AR-725-E; W=WG Reader (0=disable; 1=enable) Enabling or Disabling into Full Access status A=0:AR401RO B=0: 9600(default value) RS485 port function setting...
  • Page 9 SOYAL ® AR-725-E V220221 ACCESS CONTROL SYSTEM ※Default Value Function Option Value Application 1 :Enable Networking/Stand-Alone Turn off buzzer function ※0:Disable 1 :Enable Networking/Stand-Alone Any error trigger alarm (ex: swipe invalid card) ※0:Disable 1 :Enable Networking/Stand-Alone Reserved ※0:Disable 1 :Enable Networking/Stand-Alone Turn off 13.56MHz reading function...

This manual is also suitable for:

Ar-725-e-mAr-725-x

Table of Contents