1.Tubing: The communication wires and power line should NOT be bound in the same conduit or tubing.
2.Wire selection:Use AWG 22-24 Shielded Twist Pair to avoid star wiring ,CAT 5 cable for TCP/IP connection. Don't equip reader and lock with the same power
supply. The power for reader may be unstable when the lock is activating, that may make the reader malfunction.
3.Power supply:The standard installation: Door relay and lock use the same power supply, and reader use independent power supply.
®
3
Terminal Cables
CN4
CN5
CN6
CN3
CN8
3
Terminal Cables
CN4
CN5
CN6
CN3
3
1
4
1
2
AR-327-E / 727-E
4
Tools
Water proof Strip
4
Tools
CN7
CN2
Water proof Strip
Pull the cables from the square hole of the mounting plate.
Use a screw to the mounting plate onto the wall.
Attach the water proof strip to the body, then connect the terminal cables to the body
and attach the body to the mounting plate.
Use the Allen key and screws (accessories supplied) to assemble the body onto the
mounting plate.
Turn on the power, the LED will light and hear the beep sound, you will see "Ready""
on LCD board.
Attach the water proof strip to the mounting plate.
Pull the cables from the square hole of the mounting plate.
Use a screwdriver to screw the base onto the wall.
Connect the terminal cables to the body and attach the body to the mounting plate.
Assemble the covers with the Allen key and screws (accessories supplied).
Turn on the power, the LED will light and hear the beep sound, you will see "Ready""
on LCD board.
- 1 -
5
Optional
AR-721RB
AR-821RB
Digital Relay
5
Optional
AR-821RB
V220816
CN7
TCP/IP Module
and Cable
AR-721RB
Digital Relay

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AR-327-E and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Soyal AR-327-E

  • Page 1 SOYAL ® AR-327-E / 727-E V220816 ACCESS CONTROL SYSTEM Contents AR-327-E:Touch-panel Metal Case Products User Guide Terminal Cables Tools Optional TCP/IP Module AR-721RB AR-821RB Digital Relay and Cable Water proof Strip AR-727-E Products User Guide Terminal Cables Tools Optional AR-821RB...
  • Page 2: Installation

    WG Exit Switch Purple Negative Trigger Input Wire Application Wire Color Description Anti-Tamper N.C. Orange Switch Yellow N.O. Cable: (AR-327-E By order) Wire Application Wire Color Description Cable: TCP/IP Module Orange White Net - TX+ Wire Application Wire Color Description Orange...
  • Page 3: Front Panel & Indicator

    SOYAL ® AR-327-E / 727-E V220816 ACCESS CONTROL SYSTEM Optional Cables Cable: CN11 Cable: AR-327-E: CN10 / AR-727-E: CN18 (Optional:Lift Control w/ AR-725L485; SW:RS485-2) (Optional:Voice Module; SW:RS485-3) Wire Application Wire Color Description Wire Application Wire Color Description HID ProxII RF...
  • Page 4 Port must enabled Digital Relay Output to enable "Share Door Relay" function. AR-837-E/EE/EF/ER become WG mode 1. When AR-327-E / AR-727-E become WG mode,it can be used with any controllers. 2. Standalone Setting: Enter programming mode -> 4. Parameters(2) ->...
  • Page 5 SOYAL ® AR-327-E / 727-E V220816 ACCESS CONTROL SYSTEM Adding and Deleting Tag ※ User capacity: 16384 (00000~16383) Adding Tag by Tag ID Access programming mode → Add/Delete → Add -> Card ID → Input 5/6-digit user address → Input Site Code → Input Card Code...
  • Page 6: Restoring Factory Settings

    A. Event Logs IP Setting Open your Web Browser and input factory default IP address: http://192.168.1.127 If the IP address of AR-327-E / 727-E has changed We must enter the new IP address. Log-in User Password When you choose the "Networking Setting" or "User Password" at first.
  • Page 7 LCD Access Controller V220816 Full Function Command Menu Table Entering Input 123456 PPPPPP Down [e.g.] The Default Value= 123456. If already changed the Master Code= 876112, input 876112 → Access programming mode Esc/Quit Enter/OK P.S.If no instruction is entered within 30 sec., it will automatically leave the programming mode. 1.
  • Page 8 LCD Access Controller V220816 Full Function Command Menu Table 3. Parameters [1] 3-1. Node ID 3-2. OnOff OpenZone 3-1-1 3-1-3 3-1-5 3-1-7 3-2-1 Input New NodeID WG1 Door Number Enable DHCP Net Mask (IPv4) Main Controller Range: 001~254 0: No 1: En 2: Exit Auto Open Zone Range: 000~255 255.255.255.000...
  • Page 9 LCD Access Controller V220816 Full Function Command Menu Table 4. Parameters [2] 4-3. Miscellaneous 4-4. Force Open .. 4-5. Close & Stop 4-6. Anti-passback 4-3-10 4-3-12 4-4-1 4-5-1 4-6-1 Main Controller Lock Door Relay Main Controller Main Controller Main Controller On Egress Beeps 0: NO 1: YES Force Open Alarm...

This manual is also suitable for:

Ar-727-e

Table of Contents