Any mod- ifications to or abridgments of the document are prohibited without explicit written agreement from J. Schmalz GmbH. J. Schmalz GmbH · Johannes-Schmalz-Str. 1 · 72293 Glatten, Germany · T: +49 7443 2403-0 schmalz@schmalz.de EN-US · 30.30.01.02437 · 00 · 06/20...
ð Failure to follow the instructions in these Operating instructions may result in injuries! ð Schmalz is not liable for damage or malfunctions that result from failure to heed these instructions. If you still have questions after reading the technical documentation, contact Schmalz Service at: www.schmalz.com/services...
2.2 Non-Intended Use Schmalz does not accept any liability for any direct or indirect losses or damages that result from using the product. This applies, in particular, to any use of the product that is not in accordance with the intended purpose and to any use that is not described or mentioned in this documentation.
4 Do not look or reach into the suction cup openings. 2.7 Modifications to the Product Schmalz assumes no liability for consequences of modifications over which it has no control: 1. The product must be operated only in its original condition as delivered.
3.2 Structure of the SCG-HSS Vacuum vent Compressed air connection (max. 2.0 bar)/G 1/8"; extending the pins with a compressed air pulse; not continuously applied Thread (2 x M5) for vacuum switch holder (se- Compressed air connection (max. 6 bar)/G ries VS) – OPTIONAL 1/8";...
1. Compare the entire delivery with the supplied delivery notes to make sure nothing is missing. 2. Damage caused by defective packaging or occurring in transit must be reported immediately to the carrier and J. Schmalz GmbH. EN-US · 30.30.01.02437 · 00 · 06/20...
The flow gripper can be adapted to any handling system using the integrated thread on the housing. 4 Use the size-M5 female thread G4 to mechanically attach the SCG-HSS. Optional: Using the Mounting Set 4 Mount the mounting set on the SCG-HSS. 8 / 12 EN-US · 30.30.01.02437 · 00 · 06/20...
6.3 Connection Compressed air connection for extending the Compressed air connection for vacuum gener- pin curtain ation PE connection (ground) Optional: Vacuum connection for a vacuum switch Compressed air connection for clamping the — — pin curtain Optional: Connection for a vacuum switch on the vacuum connection (4) 1.
Page 10
2. A short compressed air pulse (1 second) is activated to extend the pins (1). Note: If a workpiece is picked up horizontally or overhead, the extension pressure must be main- tained. Based on the workpiece, a pressure on the pins of < 1.5 bar can also be selected to reduce the force on sensitive components.
4 Check the proper functioning of the product, especially the safety features, after every mainte- nance or troubleshooting operation. Designation Part no. Type ERS SCG-HSS 5S (5 pins) 10.01.30.01066 SET SCG-HSS MS (bracket mounting set) 10.01.30.01065 SD G3/8-AG 40x80 SCG (silencer) 10.01.30.00352 STV-W M5-AG 4 10.08.02.00155 STV-GE M5-AG 4 10.08.02.00200...
Screws Galvanized steel, A2 12 EC Conformity EC Declaration of Incorporation The manufacturer Schmalz confirms that the product SCG-HSS described in this Operating instructions fulfills the following applicable EC directives: 2006/42/EC Machinery Directive The product specified is solely intended for installation indoors in a complete system. Startup is prohibited until the end product has been declared to comply with the Directive 2006/42/EC.