#2: Supported loads

The Switch 2 may operate under the following loads:
Conventional incandescent light sources,
Halogen light sources,
Electrical appliances which power consumption does not exceed
the limit for a specified device.
Applied load and the Switch 2 itself may be damaged if
!
the applied load is inconsistent with the technical specifi-
cations!
When connecting the Switch 2 act in accordance with the following
rules:
Do not connect loads greater than those recommended!
Do not connect types of load other than resistive!
Rated load current table:
Device
Single Switch 2
(FGS-213)
Double Switch 2
(FGS-223)
All manuals and user guides at all-guides.com
Load
IEC standards
8A
6.5A per channel
10A overall
UL standards
6.5A
6A per channel
9.5A overall