29. S2 switch - scenes sent
This parameter determines which actions result in sending scene IDs
assigned to them.
Available settings: 1 - Key pressed 1 time
2 - Key pressed 2 times
4 - Key pressed 3 times
8 - Key Hold Down and Key Released
0
Default setting:
30. S1 switch - associations sent to 2nd and 3rd association groups
This parameter determines which actions are ignored when sending
commands to devices associated in 2nd and 3rd association group.
All actions are active by default.
Available settings: 1 - ignore turning On with 1 click of the switch
2 - ignore turning OFF with 1 click of the switch
4 - ignore holding and releasing the switch*
8 - ignore double click of the switch**
0
Default setting:
31. S1 switch - Switch ON value sent to 2nd and 3rd association
groups
This parameter defines value sent with Switch On command to devic-
es associated in 2nd and 3rd association group.
Available settings: 0-255 - sent value
Default setting:
255
32. S1 switch - Switch OFF value sent to 2nd and 3rd association
groups
This parameter defines value sent with Switch OFF command to de-
vices associated in 2nd and 3rd association group.
Available settings: 0-255 - sent value
0
Default setting:
33. S1 switch - Double Click value sent to 2nd and 3rd association
groups
This parameter defines value sent with Double Click command to de-
vices associated in 2nd and 3rd association group.
Available settings: 0-255 - sent value
99
Default setting:
All manuals and user guides at all-guides.com
Parameter size:
Parameter size:
Parameter size:
Parameter size:
Parameter size:
1 [byte]
1 [byte]
2 [bytes]
2 [bytes]
2 [bytes]
ADVAnCED PARAMETERS
19
i
NOTE
Parameter 29 values
may be combined,
e.g. 1+2=3 means that
scenes for single and
double click are sent.
i
NOTE
Parameter 30 values
may be combined, e.g.
1+2=3 means that as-
sociations for turning
On and OFF are not
sent.
i
NOTE
*Hold and release is
inactive when param-
eter 20 is set to 1 or 2.
**Double click is inac-
tive when parameter
20 is set to 1.
i
NOTE
Setting
parameters
31-33, 36-38 to appro-
priate value should re-
sult in:
0 - turning off associ-
ated devices
1-99 - forcing level of
associated devices
255 - setting associat-
ed devices to the last
remembered state or
turning them on