Repair Procedures - Daikin Comfora XP Series Service Manual

Split
Table of Contents

Advertisement

3
|
Components

3.13.2 Repair procedures

To remove the swing raster motor
Service manual
116
Pins
2-3
2-4
2-5
3-4
3-5
4-5
Swing raster motor resistance
measurements are correct?
Yes
No
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
Prerequisite: Remove the required plate work, see
1 Remove the switch box, see
2 Remove the swing raster motor cover.
a Swing raster motor cover
b Swing raster motor assembly
c Screw
3 Remove the 2 screws that fix the swing raster motor assembly to the indoor
unit.
4 Disconnect the swing raster shaft from the swing raster motor rod.
Measured resistance (Ω)
760
Action
Return to the troubleshooting of the
specific error and continue with the
next procedure.
Replace the swing raster motor, see
"3.13.2 Repair
"3.10 Plate
work" [
b
c
a
4
procedures" [
 116].
4
"3.10 Plate
work" [
 100].
4
 100].
ATXP20~35 + FTXP20~71 + ARXP20~35 + RXP20~71