3
|
Components

3.12.2 Repair procedures

To remove the swing flap motor
To install the swing flap motor
Service manual
114
Swing flap motor resistance
measurements are correct?
Yes
No
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
Prerequisite: Remove the required plate work, see
1 Remove the cover.
b
a Cover
b Screw
c Swing flap motor
2 Disconnect the connector from the swing flap motor.
3 Remove the screw from the swing flap motor.
4 Remove the swing flap motor from the swing flap.
5 To install the swing flap motor, see
1 Install the swing flap motor in the correct location on the swing flap.
Action
Return to the troubleshooting of the
specific error and continue with the
next procedure.
Replace the swing flap motor, see
"3.12.2 Repair
"3.10 Plate
c
a
"3.12.2 Repair
ATXP20~35 + FTXP20~71 + ARXP20~35 + RXP20~71
4
procedures" [
 114].
4
work" [
 100].
4
procedures" [
 114].