3.9.2 Class 50~71 units

Checking procedures
To perform a mechanical check of the propeller fan blade assembly
ATXP20~35 + FTXP20~71 + ARXP20~35 + RXP20~71
Split Comfora R32
ESIE18-01D – 2022.02
CAUTION
Do NOT install a damaged propeller fan blade assembly.
2 Install and tighten the nut to fix the propeller fan blade assembly.
a Nut
b Propeller fan blade assembly
Is the problem solved?
Yes
No
INFORMATION
It is recommended to perform the checks in the listed order.
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
Prerequisite: Remove the required plate work, see
1 If propeller fan blade touches the bell mounth, check if the fan motor is
correctly mounted on its base, see
2 Check the state of the propeller fan blade assembly for damage, deformations
and cracks.
Is the propeller fan blade assembly
damaged?
Yes
a
b
Action
No further actions required.
Return to
"Checking
of the outdoor unit fan motor and
continue with the next procedure.
"3.10 Plate
"Repair
procedures" [
Action
Replace the propeller fan blade
assembly, see
procedures" [
3
Components
|
4
procedures" [
 91]
4
work" [
 100].
4
 98].
"Repair
4
 98].