Download Print this page

SCAN 47-2 Instructions For Installation And Use page 3

Advertisement

Accessories
For this model you can have the following accessories:
Shaped floor plate in steel or glass
Connection piece for fresh-air intake
The stove can be prepared for an external air supply where
fresh air is let directly into the combustion chamber (can
also be done subsequently by the authorized dealer).
Adjustment screws
The stove has two adjustment screws on the bottom
that can be used for levelling the stove.
Data for calculation of the chimney and adjustment of the air according to EN 13240:
Combustion
Primary air
air
%
%
60
25
You should read this manual as well as the General Instructions for Installation before beginning the installation.
SCAN 47-2
Chimney
Max. fuel
draught, min.
Pa.
kg
1.5
11
Adjustment of the handle
The handle can be loosened and adjusted at the
lower closing hook with a hexagon spanner.
Handle
Pull out the handle to open.
Self-closing door (BA 1)
The door is prepared with a self-closing function at the
factory. If you tighten the spring with the hexagon spanner,
the door will close automatically when you let go of it.
Flue outlet
Temperature of
flow
flue outlet
behind flue collar
g/s
o C
7.1
195
Fuel consump-
Rated output
tion
kg/h
kW
7.4
2
Efficiency
%
84

Advertisement

loading

This manual is also suitable for:

47