1. Product Table
Unit Type Code
BExCBG05-05DPDC012
BExCBG05-05DPDC024
BExCBG05-05DPDC048
BExCBG05-05DPAC115
BExCBG05-05DPAC230
The table shows the input current taken by the various units.
Nominal current at nominal voltage.
Table 1: Electrical Ratings.
It is important that a suitable power supply is used to run the equipment. The power supply selected must have the necessary capacity
to provide the input current to all of the units.
The above table shows the input current taken by the various units and shows the maximum voltage at which they can be operated:
The input current will vary according to the voltage input level an flash rates selected.
2. Warnings
DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT
DO NOT OPEN WHEN ENERGIZED
POTENTIAL ELECTROSTATIC CHARGING HAZARD – CLEAN ONLY WITH A DAMP CLOTH
COVER BOLTS CLASS A4-80
USE HEAT RESISTING CABLES AND CABLE GLANDS (RATED 110°C) AT AMB. TEMPERATURES OVER
40°C
European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH
Document No. D210-00-701-IS
BExCBG05-05D-P
Chamber
Nominal
Beacon
Input
Nominal
Voltage
Input Current
12Vdc
750mA
24Vdc
300mA
48Vdc
180mA
115Vac
140mA
230Vac
55mA
Issue 5
12-09-2022
Cover Beacon
Max I/P Voltage
Nominal
Input Current
750mA
300mA
180mA
140mA
55mA
www.e2s.com
14V
28V
54V
126V
253V
Tel: +44 (0)208 743 8880
Sheet 1 of 7

Advertisement

Table of Contents
loading

Summary of Contents for E2S BExCBG05-05D-P

  • Page 1 INSTRUCTION MANUAL BExCBG05-05D-P Combined Beacon/ Beacon ATEx/IECEx & UKEx Gas & Dust BExCBG05-05D-P 1. Product Table Chamber Nominal Beacon Cover Beacon Unit Type Code Input Max I/P Voltage Nominal Nominal Voltage Input Current Input Current BExCBG05-05DPDC012 12Vdc 750mA 750mA BExCBG05-05DPDC024...
  • Page 2 4. Zones, Gas Group, Category and 3. Marking & Rating Information Temperature Classification The BExCBG05-05D-P Alarm Horns comply with the following The units can be installed in locations with the following conditions: standards for hazardous locations: 3.1 ATEX / IECEx & UKEx Ratings...
  • Page 3: Special Conditions For Safe Use

    Never use the cover bolts to force the cover into position. European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No. D210-00-701-IS Issue 5...
  • Page 4: Cable Connections

    Internal earthing connections should be made to the Internal Earth terminal in the base of the housing using a ring crimp European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No. D210-00-701-IS...
  • Page 5 Flip / Flop Pin Header Fig. 5b Cover DC Terminals Fig. 4b Cover AC Terminals European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No. D210-00-701-IS Issue 5 12-09-2022 Sheet 5 of 7...
  • Page 6: Line Monitoring

    12.1 Line Monitoring 14 Settings On BExCBG05-05D-P DC units, dc reverse line monitoring 14.1 Synchronised Operation can be used if required. All DC beacons have a blocking diode fitted in their supply input lines. An end of line monitoring diode...
  • Page 7: Maintenance, Overhaul & Repair

    M5x16 Hex Socket Screw equipment. M5 Spring Washer The beacon covers are interchangeable, contact E2S Ltd for a M5 Plain Washer replacement cover available in various colours. Guard To change the cover, unscrew the M5 socket head screws and remove the M5 screws, M5 spring &...
  • Page 10: Eu Declaration Of Conformity

    EN 60529:1991 + A1:2000 + A2:2013. - Degrees of protection provided by enclosures (IP code) – enclosure rated IP66/67 E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sales@e2s.com www.e2s.com DC-006_Issue_K (BExCBG)- Page 1 of 2 QAF_252_Issue_5...
  • Page 11 This Declaration is issued under the sole responsibility of the manufacturer. Martin Streetz Document No.: DC-006_Issue_K Quality Assurance Manager Date and Place of Issue: London, 23/12/2020 E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sales@e2s.com www.e2s.com DC-006_Issue_K (BExCBG)- Page 2 of 2 QAF_252_Issue_5...
  • Page 12 EN 60529:1991 / A1:2000 / A2:2013 - Degrees of protection provided by enclosures (IP code) – enclosure rated IP66/67 E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sales@e2s.com www.e2s.com DC-107_Issue_A (BExCBG)- Page 1 of 2 - QAF_252_Issue_5...
  • Page 13 This Declaration is issued under the sole responsibility of the manufacturer. Martin Streetz Document No.: DC-107_Issue_A Quality Assurance Manager Date and Place of Issue: London, 12/09/2022 E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sales@e2s.com www.e2s.com DC-107_Issue_A (BExCBG) - Page 2 of 2 - QAF_252_Issue_5...
  • Page 14 Page left Intentionally blank...
  • Page 15 Page left Intentionally blank...
  • Page 16 Page left Intentionally blank...

Table of Contents