E2S BExTBG05D-P Instruction Manual

Xenon flashtel atex/iecex & ukex gas & dust

Advertisement

Quick Links

INSTRUCTION MANUAL
BExTBG05D-P
Xenon Flashtel
ATEx/IECEx & UKEx Gas & Dust
1. Product Table
It is important that a suitable power supply is used to run the equipment. The power supply selected must have the necessary capacity
to provide the input current to all of the units.
The above table shows the input current taken by the various flashtels and shows the maximum voltage at which the flashtels can be
operated:
The input current will vary according to the voltage input level.
2. Warnings
DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT
DO NOT OPEN WHEN ENERGIZED
POTENTIAL ELECTROSTATIC CHARGING HAZARD – CLEAN ONLY WITH A DAMP CLOTH
COVER BOLTS CLASS A4-80
USE HEAT RESISTING CABLES AND CABLE GLANDS (RATED 110°C) AT AMB. TEMPERATURES OVER
40°C
European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH
Document No. D210-00-231-IS
Unit Type Code
Input Voltage
BExBTG05DPAC115
BExBTG05DPAC230
*The current levels shown above are for nominal input voltage
Issue 4
BExTBG05D-P
Nominal
Nominal
Input Current*
115Vac
140mA
230Vac
55mA
12-09-2022
Max I/P Voltage
126V
253V
www.e2s.com
Tel: +44 (0)208 743 8880
Sheet 1 of 5

Advertisement

Table of Contents
loading

Summary of Contents for E2S BExTBG05D-P

  • Page 1 INSTRUCTION MANUAL BExTBG05D-P Xenon Flashtel ATEx/IECEx & UKEx Gas & Dust BExTBG05D-P 1. Product Table Nominal Nominal Unit Type Code Max I/P Voltage Input Voltage Input Current* BExBTG05DPAC115 115Vac 140mA 126V BExBTG05DPAC230 230Vac 55mA 253V *The current levels shown above are for nominal input voltage It is important that a suitable power supply is used to run the equipment.
  • Page 2 4. Zones, Gas Group, Category and 3. Marking & Rating Information Temperature Classification The BExTBG05D-P comply with the following standards for hazardous The units can be installed in locations with the following conditions: locations: 3.1 ATEX / IECEx & UKEx Ratings...
  • Page 3: Special Conditions For Safe Use

    Never use the cover bolts to force the cover into position. European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No. D210-00-231-IS Issue 4...
  • Page 4: Cable Connections

    When using the internal earth terminal ensure that the stainless steel M4 flat washer is between the incoming earth wire and the enclosure. European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No. D210-00-231-IS Issue 4...
  • Page 5: Maintenance, Overhaul & Repair

    M5 Plain Washer equipment. Guard The flashtel cover is interchangeable, contact E2S Ltd for a Cover replacement cover available in various colours. To change the cover, unscrew the M5 socket head screws and Fig. 13 Cover and Guard Fixtures remove the M5 screws, M5 spring &...
  • Page 7 Page left Intentionally blank...
  • Page 8: Eu Declaration Of Conformity

    EN 60529:1991 + A1:2000 + A2:2013. - Degrees of protection provided by enclosures (IP code) – enclosure rated IP66/67 E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sales@e2s.com www.e2s.com DC-004_Issue_N (BExBG) - Page 1 of 2 - QAF_252_Issue_5...
  • Page 9 This Declaration is issued under the sole responsibility of the manufacturer. Martin Streetz Document No.: DC-004_Issue_N Quality Assurance Manager Date and Place of Issue: London, 20/04/2022 E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sales@e2s.com www.e2s.com DC-004_Issue_N (BExBG) - Page 2 of 2 - QAF_252_Issue_5...
  • Page 10: Equipment Type

    EN 60529:1991 / A1:2000 / A2:2013 - Degrees of protection provided by enclosures (IP code) – enclosure rated IP66/67 E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sales@e2s.com www.e2s.com DC-105_Issue_A (BExBG)- Page 1 of 2 - QAF_252_Issue_5...
  • Page 11 This Declaration is issued under the sole responsibility of the manufacturer. Martin Streetz Document No.: DC-105_Issue_A Quality Assurance Manager Date and Place of Issue: London, 12/09/2022 E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sales@e2s.com www.e2s.com DC-105_Issue_A (BExBG) - Page 2 of 2 - QAF_252_Issue_5...
  • Page 12 Page left Intentionally blank...

This manual is also suitable for:

Bexbtg05dpac115Bexbtg05dpac230

Table of Contents