INSTRUCTION MANUAL STExB2X05, STExB2X10, STExB2X15 & STExB2X21 Flameproof Xenon Beacons For use in Flammable Gas and Dust Atmospheres STExB2X05 STExB2X10 STExB2X15 STExB2X21 1) Product Table Nom. Nom. Standard Model Voltage Range Operating Max Current Voltage Current* STExB2X05DC012 12Vdc 12-14Vdc 585mA...
Page 2
X21DC024 Ex db IIC T4 Gb Ta -50°C to +65°C X21DC048 Ex tb IIIC T131°C Db Ta -50°C to +70°C E2S Warning Signals Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No. D199-00-201-IS...
Page 3
Electric Code / Canadian Electric Code. STExB2X10AC 128ºC 127 ºC STExB2X15DC STExB2X15AC 131ºC 131ºC STExB2X21DC 142ºC STExB2X21AC E2S Warning Signals Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No. D199-00-201-IS Issue 5 28-11-22 Sheet 3 of 8...
Fully tighten the cover all the way, ensure no gap is visible between the cover and base of the beacon enclosure. Tighten the M4 grub screw. E2S Warning Signals Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No.
Page 5
PCBA, using solid wire 0.5-4mm2 / AWG 20-12 or stranded wire, sizes 0.5-2.5mm2 / AWG 24-14. Wire insulation needs to be stripped 8mm. Wires may be fitted securely with crimped ferrules. E2S Warning Signals Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No.
Page 6
50mm, whichever is the lesser. E2S Warning Signals Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No.
Page 7
The resistor must be connected directly across the +ve and - ve terminals as shown in the following drawing. The resistor leads should be kept as short as possible. E2S Warning Signals Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No.
Repair of the flameproof threaded joints and cemented joints is not permitted. Potential electrostatic charging hazard - Clean only with a damp cloth. E2S Warning Signals Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No.
Page 10
WRITTEN CONSENT. IMPRESS HOUSE 03/07/19 R.N.POTTS STANDARDS MANSELL ROAD EUROPEAN SAFETY SYSTEMS LTD. ACTON DRAWING NUMBER ALTERNATIVE MATERIAL AS PER LATEST DATE OF ISSUE SHOWN ABOVE LONDON W3 7QH SCALE SHEET APPROVED DATE STExB2 BEACONS WWW.E2S.COM D199-06-201 NTS 1 03/07/19 R.N.POTTS...
Page 11
WRITTEN CONSENT. IMPRESS HOUSE 03/07/19 R.N.POTTS STANDARDS MANSELL ROAD EUROPEAN SAFETY SYSTEMS LTD. ACTON DRAWING NUMBER AS PER LATEST DATE OF ISSUE SHOWN ABOVE LONDON W3 7QH SCALE SHEET ALTERNATIVE MATERIAL APPROVED DATE STExB2 BEACONS WWW.E2S.COM D199-06-201 NTS 2 03/07/19 R.N.POTTS...
E2S Warnsignaltechnik UG Charlottenstrasse 45‐51 72764 Reutlingen Germany Equipment Type: STExS1, STExS2, STExL1, STExL2 STExB2X05, STExB2X10, STExB2X15, STExB2X21 STExB2LD2, STExB2RT1 STExC1X05 STExJ2 Directive 2014/34/EU: Equipment and Protective Systems for use in Potentially Explosive Atmospheres (ATEX) Notified Body for EU type Examination (Module B): UL International Demko A/S Notified Body No.: 0539 Borupvang 5A, 2750 Ballerup, Denmark EU‐type Examination Certificate (Module B): DEMKO 16ATEX1466X ...
Page 13
EU Declaration of Conformity On behalf of European Safety Systems Ltd., I declare that, on the date the equipment accompanied by this declaration is placed on the market, the equipment conforms with all technical and regulatory requirements of the above listed directives, regulations and standards. This Declaration is issued under the sole responsibility of the manufacturer. Martin Streetz Document No.: DC‐070_Issue_G Quality Assurance Manager Date and Place of Issue: London, 03/12/2021 E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sales@e2s.com www.e2s.com DC‐070_Issue_G (STEx).docx ‐ Page 2 of 2 ‐ QAF_252_Issue_5...
Page 14
European Safety Systems Ltd. Impress House, Mansell Road, Acton London, W3 7QH United Kingdom Equipment Type: STExS1, STExS2, STExL1, STExL2 STExB2X05, STExB2X10, STExB2X15, STExB2X21 STExB2LD2, STExB2RT1 STExC1X05 STExJ2 Directive UKSI 2016:1107 (as amended by UKSI 2019:696) – Schedule 3A, Part 1 : Product or Protective System Intended for use in Potentially Explosive Atmospheres (UKCA) Notified Body for UK type Examination (Module B): UL International (UK) Ltd Notified Body No.: 0843 Unit 1‐3 Horizon Kingsland Business Park, Wade Road, ...
Page 15
UKCA Declaration of Conformity On behalf of European Safety Systems Ltd., I declare that, on the date the equipment accompanied by this declaration is placed on the market, the equipment conforms with all technical and regulatory requirements of the above listed directives, regulations and standards. This Declaration is issued under the sole responsibility of the manufacturer. Martin Streetz Document No.: DC‐100_Issue_A Quality Assurance Manager Date and Place of Issue: London, 24/02/2022 E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sales@e2s.com www.e2s.com DC‐100_Issue_A (STEx) ‐ Page 2 of 2 ‐ QAF_252_Issue_5...