E2S D2xB1X05 Instruction Manual

Xenon beacons for use in hazardous locations
Hide thumbs Also See for D2xB1X05:

Advertisement

Quick Links

INSTRUCTION MANUAL
D2xB1X05 & D2xB1X10 Xenon Beacons
For use in Hazardous Locations
1) Product Table
D2xB1X05DC024
D2xB1X05DC048
D2xB1X05AC115
D2xB1X05AC230
D2xB1X10DC024
D2xB1X10DC048
D2xB1X10AC115
D2xB1X10AC230
Table 1: Electrical Ratings.
2) Warnings
 DO NOT OPEN WHEN AN EXPLOSIVE
ATMOSPHERE IS PRESENT
 DO NOT OPEN WHEN ENERGISED
 POTENTIAL ELECTROSTATIC CHARGING
HAZARD - CLEAN ONLY WITH A DAMP
CLOTH
 HIGH VOLTAGE SHOCK HAZARD. WAIT 5
MINUTES AFTER REMOVING POWER
BEFORE OPENING THE ENCLOSURE
Avertissement:
 NE PAS OUVRIR UN PRESENCE
D'ATMOSPHERE EXPLOSIVE
 NE PAS OUVRIR ENERGIE
 DANGER POTENTIEL CHARGE
ÉLECTROSTATIQUE - NETTOYER
UNIQUEMENT AVEC UN CHIFFON HUMIDE
 HAUT TENSION, RISK DE CHOC.
ATTENDEZ 5 MINUTES APRES AVOIR
DEBRANCHE L'ALIMENTATION AVANT
D'OUVRIR LA BOITIER
European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH
Document No. D211-00-201-IS
Model
Issue 1
D2XB1X05
D2XB1X10
Nom. Voltage
24Vdc
48Vdc
115Vac
115-120Vac 50/60Hz
230Vac
220-230Vac 50/60Hz
24Vdc
48Vdc
115Vac
115-120Vac 50/60Hz
230Vac
220-230Vac 50/60Hz
3) Rating & Marking Information
All units have a rating label, which carries the following
important information:
Unit Model.
Voltage Range
Nominal Voltage
See Table 1 for electrical ratings of each Unit Model.
3.1. Fire Alarm Ratings
The Following models are certified as visual alarm devices for
private mode visual alarm devices in accordance with
UL1638 Fifth Edition / CAN/ULC-S526 Fourth Edition when
used with clear or red lens covers:
D2XB1X05DC024 ; D2XB1X05DC048
D2XB1X10DC024 ; D2XB1X10DC048
See fire instruction manual D211-00-201-IS-SC-UL
20-08-22
Voltage Range
20-28Vdc
48Vdc
20-28Vdc
48Vdc
www.e2s.com
Operating
rms Current
296mA
145mA
80mA
30mA
609mA
260mA
185mA
107mA
Tel: +44 (0)208 743 8880
Sheet 1 of 6

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the D2xB1X05 and is the answer not in the manual?

Questions and answers

Summary of Contents for E2S D2xB1X05

  • Page 1 INSTRUCTION MANUAL D2xB1X05 & D2xB1X10 Xenon Beacons For use in Hazardous Locations D2XB1X05 D2XB1X10 1) Product Table Operating Model Nom. Voltage Voltage Range rms Current D2xB1X05DC024 24Vdc 20-28Vdc 296mA D2xB1X05DC048 48Vdc 48Vdc 145mA D2xB1X05AC115 115Vac 115-120Vac 50/60Hz 80mA D2xB1X05AC230 230Vac...
  • Page 2 Class II Div 2 FG T5 Ta -40°C to +45°C Class III Div 1&2 Ta -40°C to +50°C European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No. D211-00-201-IS Issue 1...
  • Page 3: Special Conditions Of Use

    Ambient Temperature Range Fig. 1 Fixing Location for Beacon -40°C to +70°C IP Rating European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No. D211-00-201-IS Issue 1 20-08-22 Sheet 3 of 6...
  • Page 4: Cable Connections

    PCBA located in the enclosure. See section 6 of this manual for access to the enclosure. Fig. 6a D2xB1X05/D2xB1X10 48 VDC Terminals Wires having a cross sectional area between 0.5 mm² to 2.5mm² can be connected to each terminal way. If an input and output wire is required the 2-off Live/Neutral or +/- terminals can be used.
  • Page 5 +ve and –ve terminals. If an end of line resistor is used it must have the following values: The Beacon lens cover is interchangeable, contact E2S Ltd for a replacement lens cover available in various colours. Min. Resistance Min.
  • Page 6: Dip Switch

    If opening the unit during maintenance operations a clean environment must be maintained and any dust layer removed prior to opening the unit. European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No. D211-00-201-IS Issue 1...
  • Page 7 FIRE INSTRUCTION MANUAL D2xB1X05 & D2xB1X10 Xenon Beacons For use in Hazardous Locations 1) Warnings  DO NOT PAINT Avertissement:  NE PAS PEINTURER 2) Rating & Marking Information 2.1 Fire Alarm Ratings The Following models are certified as visual alarm devices for private mode visual alarm devices in accordance with UL1638 Fifth...
  • Page 8 ISSUE MOD No. REASON - INITIAL - DATE INTRODUCTION RSR 02-01-2020 UPDATED FORMAT DH 17-05-2022 DC XENON D2XB1X05 / X10 UNITS AC D2XB1X05 / X10 UNITS Line Monitoring Power: Live & Neutral Power: +ve & -ve -ve OUT LIVE OUT...
  • Page 9: Eu Declaration Of Conformity

    Other Standards and Regulations EN 60529:1992+A2:2013 - Degrees of protection provided by enclosures (IP code) – enclosure rated IP66 E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sales@e2s.com www.e2s.com DC-061_Issue_J (D2x).docx - Page 1 of 2 - QAF_252_Issue_5...
  • Page 10 This Declaration is issued under the sole responsibility of the manufacturer. Martin Streetz Document No.: DC-061_Issue_J Quality Assurance Manager Date and Place of Issue: London, 22/08/2022 E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sales@e2s.com www.e2s.com DC-061_Issue_J (D2x).docx - Page 2 of 2 - QAF_252_Issue_5...
  • Page 11 Other Standards and Regulations EN 60529:1992+A2:2013 ‐ Degrees of protection provided by enclosures (IP code) – enclosure rated IP66 E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sales@e2s.com www.e2s.com DC-102_Issue_A - Page 1 of 2 - QAF_252_Issue_5...
  • Page 12 This Declaration is issued under the sole responsibility of the manufacturer. Martin Streetz Document No.: DC‐102_Issue_A Quality Assurance Manager Date and Place of Issue: London, 22/08/2022 E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sales@e2s.com www.e2s.com DC-102_Issue_A - Page 2 of 2 - QAF_252_Issue_5...

Table of Contents