INSTRUCTION MANUAL
GNExB1X05
Flameproof Xenon Beacons
For use in Flammable Gas and Dust Atmospheres
1) Product Table
Standard
ATEX /
IECEx /
UKEX
*Rate at 1Hz
The table shows the input current taken by the various beacons.
A supply voltage variation of +/-10% outside the voltage range is permissible.
Nominal current at nominal voltage and 1Hz flash rate.
Max. rated current at worst case supply voltage and flash rate.
Table 1: Electrical Ratings.
Ensure the system power supply is capable of providing the maximum current required for all beacons. Review associated cable
size, length and quantity of beacons on each circuit.
2) Warnings
POTENTIAL ELECTROSTATIC CHARGING HAZARD
DO NOT OPEN WHEN AN EXPLOSIVE
ATMOSPHERE IS PRESENT
ALL ENTRIES M20 X 1.5
IF TEMPERATURE EXCEEDS 70ºC AT ENTRY OR 80ºC
AT BRANCHING POINT USE SUITABLE RATED CABLE
AND CABLE GLANDS
3) Marking & Rating Information
All units have a rating label, which carries the following
important information:-
Unit Model.
Voltage Range
Nominal Voltage
Max. Current
_______________________________________________________________________________________________________________________________
European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH
Document No.D155-00-201-IS
Model
GNExB1X05DC012
GNExB1X05DC024
GNExB1X05DC048
GNExB1X05AC115
GNExB1X05AC230
Issue 3
28-11-22
GNExB1X05
Nom.
Voltage Range
Voltage
12Vdc
10-14Vdc
24Vdc
20-28Vdc
48Vdc
42-54Vdc
115Vac
110-125Vac 50/60Hz
230Vac
220-240Vac 50/60Hz
See Table 1 for electrical ratings of each Unit Model
3.1) ATEX / IECEx / UKEX Ratings
EN IEC 60079-0:2018 / IEC60079-0:2017 (Ed 7):
Explosive Atmospheres - Equipment. General Requirements
EN60079-1:2014 / IEC60079-1:2014 (Ed 7):
Explosive Atmospheres - Equipment Protection by Flameproof
Enclosures "d"
EN 60079-31:2014 / IEC 60079-31:2013 (Ed 2):
Explosive Atmospheres - Equipment Dust Ignition Protection by
Enclosure "t"
GNExB2:
Ex db IIC Gb T6 Ta -50°C to +40°C
X05DC012
Ex db IIC Gb T5 Ta -50°C to +55°C
X05DC024
Ex db IIC Gb T4 Ta -50°C to +70°C
X05DC048
Ex tb IIIC Db T110°C Ta -50°C to +70°C
X05AC115
X05AC230
www.e2s.com
Sheet 1 of 5
Nom.
Max
Operating
Current
Current*
437mA
587mA
254mA
266mA
158mA
175mA
95mA
121mA
54mA
88mA
Standards
Ratings
Tel: +44 (0)208 743 8880
Need help?