OPERATION
CONTROL PANEL
Blower Motor Switch
Fan speed is controlled with a rotary switch. On front A/C-
heater systems, there are 4 different fan speed settings. Low, medium-
low, medium-high, and high. On rear A/C-heater systems, there are 3
different fan speed settings. Low, medium, and high.
Mode Control Knob
Mode rotary switch is used to change direction of air flow.
There are 7 different modes of operation: recirculation, panel with
A/C, floor/panel, panel without A/C (vent), floor, floor/defrost, and
defrost.
Temperature Control Knob
Temperature rotary switch controls temperature blend/air door
position by a cable on Dakota and Durango, and by vacuum actuator for
Ram Pickup. When cold temperature is selected, no air flows across
heater core. When hot temperature is selected, all air flows through
heater core. Temperature may vary by any setting between cold and hot.
CLUTCH CYCLING PRESSURE SWITCH
Dakota & Ram Pickup
Clutch cycling low pressure switch is mounted on a Schrader-
type valve fitting that is part of the accumulator. It is connected in
series with the high pressure cut-off switch and control panel,
between ground and PCM. Switch contacts open and close due to changes
in A/C system pressure. Opening and closing of switches will cause PCM
to turn compressor clutch on and off, regulating system pressure which
controls temperature of evaporator.
Clutch cycling low pressure switch contacts are normally open
when suction (low side) pressure drops below 25 psi (1.8 kg/cm
Ram Pickup; 20.5 psi (1.4 kg/cm
also open contacts. When contacts are open, PCM will de-energize
compressor clutch relay, disengaging compressor clutch.
Clutch cycling pressure switch contacts will close when
suction (low side) pressure rises above 43 psi (3.0 kg/cm
Pickup or 36 psi (2.5 kg/cm
will energize compressor clutch relay, engaging compressor clutch.
ELECTRONIC CYCLING CLUTCH SWITCH
Durango
The electronic cycling clutch switch is mounted to Thermal
Expansion Valve (TXV), also referred to as an "H" valve, in engine
compartment. It provides evaporator temperature to the PCM. Using this
information, the PCM will cycle the compressor clutch to prevent
evaporator icing. The switch is used for the front evaporator only.
Electronic cycling clutch switch is connected in series with
mode control switch, high pressure cut-out switch, low pressure cut-
out switch, and PCM. The electronic cycling clutch switch opens when
refrigerant temperature is below about 37
when refrigerant temperature is about 40
FIXED ORIFICE TUBE
Dakota & Ram Pickup
The fixed orifice tube is located in outlet line of the
condenser. The orifice tube inlet and outlet ends have a screen to
¢
) on Dakota. Extreme cold weather will
¢
) on Dakota. When contacts are closed, PCM
£
F (2.8
£
F (4.4
¢
) on
¢
) on Ram
£
C) and will close
£
C).