Reissued: 3-Dec-03
Model:
Model U-P1
SP2
New defaults (Old default)
310*
PaperTrans_LL1 (Paper Transfer LL1)
The display indicates: Paper Weight/Side 1 or 2/Paper Width (mm)
1
Nrml/1st/-297
2
Nrml/1st/257-296
3
Nrml/1st/210-256
4
Nrml/1st/129-209
5
Nrml/1st/-128
6
Mid/1st/-297
7
Mid/1st/257-296
8
Mid/1st/210-256
9
Mid/1st/129-209
10
Mid/1st/-128
11
Thk/1st/-297
12
Thk/1st/257-296
13
Thk/1st/210-256
14
Thk/1st/129-209
15
Thk/1st/-128
16
Nrml/2nd/-297
17
Nrml/2nd/257-296
18
Nrml/2nd/210-256
19
Nrml/2nd/129-209
20
Nrml/2nd/-128
21
Mid/2nd/-297
22
Mid/2nd/257-296
23
Mid/2nd/210-256
24
Mid/2nd/129-209
25
Mid/2nd/-128
26
Thk/2nd/-297
27
Thk/2nd/257-296
28
Thk/2nd/210-256
29
Thk/2nd/129-209
30
Thk/2nd/-128
31
OHP/297
32
OHP/210
311*
PaperTrans_LL2 (Paper Transfer LL2)
The display indicates: Paper Weight/Side 1 or 2/Paper Width (mm)
1
Nrml/1st/-297
311*
2
Nrml/1st/257-296
T
B
echnical
Sets the paper transfer current when absolute humidity
3
AH (g/m
) is in the following range:
0 < AH ≤ 3.5 (this is the 'LL1' humidity range)
Adjust only if there are problems with insufficient transfer
in the image area of the copy for a particular paper type
or mode, or in response to field problems as directed by
technical support staff.
[0 ~ 70.0 / 25.0 (32.0) / 0.2 µA/step]
[0 ~ 70.0 / 25.0 (34.0) / 0.2 µA/step]
[0 ~ 70.0 / 25.0 (36.0) / 0.2 µA/step]
[0 ~ 70.0 / 25.0 (39.0) / 0.2 µA/step]
[0 ~ 70.0 / 25.0 (42.0 / 0.2 µA/step]
[0 ~ 70.0 / 26.0 (33.0) / 0.2 µA/step]
[0 ~ 70.0 / 26.0 (35.0) / 0.2 µA/step]
[0 ~ 70.0 / 26.0 (37.0) / 0.2 µA/step]
[0 ~ 70.0 / 26.0 (40.0) / 0.2 µA/step]
[0 ~ 70.0 / 26.0 (43.0) / 0.2 µA/step]
[0 ~ 70.0 / 14.0 (16.0) / 0.2 µA/step]
[0 ~ 70.0 / 15.0 (19.0) / 0.2 µA/step]
[0 ~ 70.0 / 16.0 (21.0) / 0.2 µA/step]
[0 ~ 70.0 / 18.0 (24.0) / 0.2 µA/step]
[0 ~ 70.0 / 20.0 (27.0) / 0.2 µA/step]
[0 ~ 70.0 / 28.0 (38.0) / 0.2 µA/step]
[0 ~ 70.0 / 30.0 (40.0) / 0.2 µA/step]
[0 ~ 70.0 / 28.0 (42.0) / 0.2 µA/step]
[0 ~ 70.0 / 28.0 (43.0) / 0.2 µA/step]
[0 ~ 70.0 / 28.0 (44.0) / 0.2 µA/step]
[0 ~ 70.0 / 29.0 (39.0) / 0.2 µA/step]
[0 ~ 70.0 / 31.0 (41.0) / 0.2 µA/step]
[0 ~ 70.0 / 29.0 (43.0) / 0.2 µA/step]
[0 ~ 70.0 / 29.0 (44.0) / 0.2 µA/step]
[0 ~ 70.0 / 29.0 (45.0) / 0.2 µA/step]
[0 ~ 70.0 / 12.0 (16.0) / 0.2 µA/step]
[0 ~ 70.0 / 16.0 (19.0) / 0.2 µA/step]
[0 ~ 70.0 / 20.0 (21.0) / 0.2 µA/step]
[0 ~ 70.0 / 24.0 / 0.2 µA/step]
[0 ~ 70.0 / 28.0 (26.0) / 0.2 µA/step]
[0 ~ 70.0 / 16.0 / 0.2 µA/step]
[0 ~ 70.0 / 20.0 (22.0) / 0.2 µA/step]
Sets the paper transfer current when absolute humidity
3
AH (g/m
) is in the following range:
3.5 < AH ≤ 8.0 (this is the 'LL2' humidity range)
See SP2-310 for comments.
[0 ~ 70.0 / 27.0 (36.0) / 0.2 µA/step]
[0 ~ 70.0 / 28.0 (38.0) / 0.2 µA/step]