Ricoh GW Series Technical Bulletin page 40

Advertisement

Reissued: 17-Jun-03
Model:
Model U-P1
SP1-105 -01 (Fusing Temperature): Default for idling start changed from 145 to 140
(see SP mode table below).
SP2-801 -02 (Additional Value of the charge corona cleaning interval) has been newly
added. The cleani ng interval for the additional charge corona unit has been adjusted
as shown.
[0 ~ 5000 / 100 / 100 counts/step]
With this new SP, it is possible to adjust the interval for charge corona cleaning in the
middle of a job:
Old:
The charge corona cleaning is carried out after 600 (SP2-801-1) development
counts, at job end or after 700 (no adjustment ) development counts (stops in the
middle of the job).
After
The charge corona cleaning is carried out after 600 (SP2-801-1) development
counts, at job end or after 700 (= the sum of the settings in SP2-801-1 and -2)
development counts (stops in the middle of the job).
Hardware Ethernet Problem: For details, please refer to General RTB #RGene012.
Selecting HDD font or DIMM font may sometimes reduce available memory.
Printing speed is sometimes low when printing an AutoCAD file.
Machine may freeze during printing when using a certain application w/HDD font or
DIMM font selection.
Text characters may appear darker with a certain raster image.
Graphics objects may appear darker when available memory is low.
Wireless LAN card sometimes cannot communicate with the printer when the WEP
key is ON.
Translation corrections for some words in Polish and German.
l
SP1-905 -01 (pressure roller type) has been newly added.
0 : new pressure roller type (2.1mm), 1 : old pressure roller type (1.5mm)
This has been added due to the pressure roller modification applied to prevent fusing
jams (wrapping around the pressure roller), whereby the layer thickness of the
pressure roller was changed from 1.5 mm to 2.1mm from first production.
NOTE : When updating from v2.19 or former to v2.20 or later, it is necessary to
manually enter a value of 0 into this SP mode and then press # , which instructs the
machine to use the new data for fusing control.
l
Some default values of SP1 -105 (Fusing Temperature) have been changed.
See new default table below. (new settings input from August '02 production).
T
echnical
Symptom Corrected
B
ulletin
Date:
3-Feb -03
PAGE: 4/11
No.:
RG071003b
Version
V2.24
V2.22.1
V2.22
V2.21
V2.20